Adhesion forces measured at the level of a terminal plate of the fly's seta
Open accessThe DOI matches its Crossref record.
Abstract
The attachment pads of fly legs are covered with setae, each ending in small terminal plates coated with secretory fluid. A cluster of these terminal plates contacting a substrate surface generates strong attractive forces that hold the insect on smooth surfaces. Previous research assumed that cohesive forces and molecular adhesion were involved in the fly attachment mechanism. The main elements that contribute to the overall attachment force, however, remained unknown. Multiple local force-volume measurements were performed on individual terminal plates by using atomic force microscopy. It was shown that the geometry of a single terminal plate had a higher border and considerably lower centre. Local adhesion was approximately twice as strong in the centre of the plate as on its border. Adhesion of fly footprints on a glass surface, recorded within 20 min after preparation, was similar to adhesion in the centre of a single attachment pad. Adhesion strongly decreased with decreasing volume of footprint fluid, indicating that the layer of pad secretion covering the terminal plates is crucial for the generation of a strong attractive force. Our data provide the first direct evidence that, in addition to Van der Waals and Coulomb forces, attractive capillary forces, mediated by pad secretion, are a critical factor in the fly's attachment mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Looking Beyond Fibrillar Features to Scale Gecko‐Like Adhesion
Bartlett, M. D., Croll, A. B., King, D. R., Paret, B. M., Irschick, D. J., & Crosby, A. J. (2012) · Advanced Materials · doi:10.1002/adma.201104191 · Cited by 317
Drechsler, P., & Federle, W. (2006) · Journal of Comparative Physiology A · doi:10.1007/s00359-006-0150-5 · Cited by 214
“The presence of a liquid Wlm sandwiched between the pad cuticle and the surface has given rise to models of “wet adhesion”, which explain the insects’ sticking ability by the capillarity and viscosity of the Xuid Wlm (Dewitz 1884; Stork 1980; Walker 1993; Walker et al. 1985; Lees and Hardie 1988; Langer et al. 2004 ).”
BackgroundBullock, J. M. R., Drechsler, P., & Federle, W. (2008) · Journal of Experimental Biology · doi:10.1242/jeb.020941 · Cited by 172
“Unlike the ‘dry’ adhesives of spiders and geckos, both smooth and fibrillar adhesive systems in insects require the use of a secreted fluid (Betz, 2003; Eisner and Aneshansley, 2000; Federle et al., 2002; Gorb, 1998; Langer et al., 2004).”
Background
Metadata
- Authors
- Langer, M. G., Ruppersberg, J. P., & Gorb, S.
- Venue
- Proceedings of the Royal Society of London. Series B: Biological Sciences
- Publisher
- The Royal Society
- Published
- 2004-11-07
- Volume
- 271
- Issue
- 1554
- Pages
- 2209-2215
- ISSN
- 0080-4649 (ISSN-L)
- 0962-8452
- 1471-2954
- OpenAlex
- W1982618503
- Cited by
- 137
- References
- 0
- FWCI
- 11.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adhesion forces measured at the level of a terminal plate of the fly's seta. https://app.cochat.ai/papers/10.1098/rspb.2004.2850
- The paper
- Langer, M. G., Ruppersberg, J. P., & Gorb, S. (2004). Adhesion forces measured at the level of a terminal plate of the fly's seta. Proceedings of the Royal Society of London. Series B: Biological Sciences. https://doi.org/10.1098/rspb.2004.2850
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.