Modelling cardiac fluid dynamics and diastolic function
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Two complementary mathematical modelling approaches are covered. They contrast the degree of mathematical and computational sophistication that can be applied to cardiovascular physiology problems and they highlight the differences between a fluid dynamic versus kinematic (lumped parameter) approach. McQueen & Peskin model cardiovascular tissue as being incompressible, having essentially uniform mass density, and apply a modified form of the Navier–Stokes equations to the four chambered heart and great vessels. Using a supercomputer their solution provides fluid, wall and valve motion as a function of space and time. Their computed results are consistent with flow attributes observed in vivo via cardiac MRI. Kovács focuses on the physiology of diastole. The suction pump attribute of the filling ventricle is modelled as a damped harmonic oscillator. The model predicts transmitral flow–velocity as a function of time. Using the contour of the clinical Doppler echocardiographic Eand A–wave as input, unique solution of Newton's Law allows solution of the ‘inverse problem’ of diastole. The model quantifies diastolic function in terms of model parameters accounting for (lumped) chamber stiffness, chamber viscoelasticity and filling volume. The model permits derivation of novel (thermodynamic) indexes of diastolic function, facilitates non–invasive quantitation of diastolic function and can predict ‘new’ physiology from first principles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thompson, D. W. (1992) · doi:10.1017/cbo9781107325852 · Cited by 443
Cited by
Peskin, C. S. (2002) · Acta Numerica · doi:10.1017/s0962492902000077 · Cited by 4,603
Self-citationModeling the Heart--from Genes to Cells to the Whole Organ
Noble, D. (2002) · Science · doi:10.1126/science.1069881 · Cited by 622
Hunter, P. J., Pullan, A. J., & Smaill, B. H. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121537 · Cited by 291
Quarteroni, A., Lassila, T., Rossi, S., & Ruiz-Baier, R. (2017) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2016.05.031 · Cited by 248
“nor thin-wall assumptions hold, the only feasible formulations of the problem fall roughly in two categories: ones using a moving mesh approach with an Arbitrary Lagrangian–Eulerian (ALE) formulation to account for the domain velocity in the NSE [94–96,4,97,8,3], and those using the immersed boundary (IB) method [98,2…”
MethodChabiniok, R., Wang, V. Y., Hadjicharalambous, M., Asner, L., Lee, J., Sermesant, M., Kuhl, E., Young, A. A., Moireau, P., Nash, M. P., et al. (2016) · Interface Focus · doi:10.1098/rsfs.2015.0083 · Cited by 234
“These models, representing the myocardium as a collection of 1D fibres, were used to study coupling between flow and tissue along with the interaction between chambers of the heart [25,145–147].”
MethodWatanabe, H., Sugiura, S., Kafuku, H., & Hisada, T. (2004) · Biophysical Journal · doi:10.1529/biophysj.103.035840 · Cited by 226
“Although Peskin and colleagues (Kovacs et al., 2001; McQueen and Peskin, 2000), using immersed boundary method, reported the detailed flow mapping in the four chambers of the heart and great vessels, their methodology, in principle, does not allow one to incorporate the subcellular mechanisms to…”
BackgroundMethodDuration of diastole and its phases as a function of heart rate during supine bicycle exercise
Chung, C. S., Karamanoglu, M., & Kovács, S. J. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00404.2004 · Cited by 174
“Kinematic modeling (18, 19) idealizes the physiology by treating the recoil process as mechanical oscillations unrelated to the overall contraction-recoil cycle frequency, i.”
Self-citationNguyen, T. D., Kadri, O. E., & Voronov, R. S. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.529365 · Cited by 19
Metadata
- Authors
- Kovács, S. J., Mcqueen, D. M., & Peskin, C. S.
- Venue
- Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences
- Publisher
- The Royal Society
- Published
- 2001-06-15
- Volume
- 359
- Issue
- 1783
- Pages
- 1299-1314
- ISSN
- 1364-503X (ISSN-L)
- 1471-2962
- OpenAlex
- W2013141599
- Cited by
- 90
- References
- 1
- FWCI
- 4.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.