The DOI matches its Crossref record.
Near-field microscopy by elastic light scattering from a tip
Abstract
We describe ultraresolution microscopy far beyond the classical Abbe diffraction limit of one half wavelength (lambda/2), and also beyond the practical limit (ca. lambda/10) of aperture-based scanning near-field optical microscopy (SNOM). The 'apertureless' SNOM discussed here uses light scattering from a sharp tip (hence scattering-type or s-SNOM) and has no lambda-related resolution limit. Rather, its resolution is approximately equal to the radius a of the probing tip (for commercial tips, a < 20 nm) so that 10 nm is obtained in the visible (lambda/60). A resolution of lambda/500 has been obtained in the mid-infrared at lambda = 10 microm. The advantage of infrared, terahertz and even microwave illumination is that specific excitations can be exploited to yield specific contrast, e.g. the molecular vibration offering a spectroscopic fingerprint to identify chemical composition. S-SNOM can routinely acquire simultaneous amplitude and phase images to obtain information on refractive and absorptive properties. Plasmon- or phonon-resonant materials can be highlighted by their particularly high near-field signal level. Furthermore, s-SNOM can map the characteristic optical eigenfields of small, optically resonant particles. Lastly, we describe theoretical modelling that explains and predicts s-SNOM contrast on the basis of the local dielectric function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical nano-imaging of gate-tunable graphene plasmons
Chen, J., Badioli, M., Alonso-González, P., Thongrattanasiri, S., Huth, F., Osmond, J., Spasenović, M., Centeno, A., Pesquera, A., Godignon, P., et al. (2012) · Nature · doi:10.1038/nature11254 · Cited by 2,107
Self-citationMott Transition in VO 2 Revealed by Infrared Spectroscopy and Nano-Imaging
Qazilbash, M. M., Brehm, M., Chae, B.-G., Ho, P.-C., Andreev, G. O., Kim, B.-J., Yun, S. J., Balatsky, A. V., Maple, M. B., Keilmann, F., et al. (2007) · Science · doi:10.1126/science.1150124 · Cited by 1,539
Self-citationTopological valley transport at bilayer graphene domain walls
Ju, L., Shi, Z., Nair, N., Lv, Y., Jin, C., Velasco, J., Ojeda-Aristizabal, C., Bechtel, H. A., Martin, M. C., Zettl, A., et al. (2015) · Nature · doi:10.1038/nature14364 · Cited by 680
Controlling the near-field oscillations of loaded plasmonic nanoantennas
Schnell, M., García-Etxarri, A., Huber, A. J., Crozier, K., Aizpurua, J., & Hillenbrand, R. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.46 · Cited by 466
Self-citationTip‐Enhanced Near‐Field Optical Microscopy
Hartschuh, A. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200801605 · Cited by 295
Metadata
- Authors
- Keilmann, F., & Hillenbrand, R.
- Venue
- Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences
- Publisher
- The Royal Society
- Published
- 2004-04-15
- Volume
- 362
- Issue
- 1817
- Pages
- 787-805
- ISSN
- 1364-503X (ISSN-L)
- 1471-2962
- OpenAlex
- W1481377485
- Cited by
- 705
- References
- 0
- FWCI
- 11.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Near-field microscopy by elastic light scattering from a tip. https://app.cochat.ai/papers/10.1098/rsta.2003.1347
- The paper
- Keilmann, F., & Hillenbrand, R. (2004). Near-field microscopy by elastic light scattering from a tip. Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences. https://doi.org/10.1098/rsta.2003.1347
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.