The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Heterogeneous three-dimensional anatomical and electrophysiological model of human atria
Abstract
Investigating the mechanisms underlying the genesis and conduction of electrical excitation in the atria at physiological and pathological states is of great importance. To provide knowledge concerning the mechanisms of excitation, we constructed a biophysical detailed and anatomically accurate computer model of human atria that incorporates both structural and electrophysiological heterogeneities. The three-dimensional geometry was extracted from the visible female dataset. The sinoatrial node (SAN) and atrium, including crista terminalis (CT), pectinate muscles (PM), appendages (APG) and Bachmann's bundle (BB) were segmented in this work. Fibre orientation in CT, PM and BB was set to local longitudinal direction. Descriptions for all used cell types were based on modifications of the Courtemanche et al . model of a human atrial cell. Maximum conductances of , and were modified for PM, CT, APG and atrioventricular ring to reproduce measured action potentials (AP). Pacemaker activity in the human SAN was reproduced by removing , but including , , and gradients of channel conductances as described in previous studies for heterogeneous rabbit SAN. Anisotropic conduction was computed with a monodomain model using the finite element method. The transversal to longitudinal ratio of conductivity for PM, CT and BB was 1 : 9. Atrial working myocardium (AWM) was set to be isotropic. Simulation of atrial electrophysiology showed initiation of APs in the SAN centre. The excitation spread afterwards to the periphery near to the region of the CT and preferentially towards the atrioventricular region. The excitation extends over the right atrium along PM. Both CT and PM activated the right AWM. Earliest activation of the left atrium was through BB and excitation spread over to the APG. The conduction velocities were 0.6 m s −1 for AWM, 1.2 m s −1 for CT, 1.6 m s −1 for PM and 1.1 m s −1 for BB at a rate of 63 bpm. The simulations revealed that bundles form dominant pathways for atrial conduction. The preferential conduction towards CT and along PM is comparable with clinical mapping. Repolarization is more homogeneous than excitation due to the heterogeneous distribution of electrophysiological properties and hence the action potential duration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The sinoatrial node, a heterogeneous pacemaker structure
Boyett, M. (2000) · Cardiovascular Research · doi:10.1016/s0008-6363(00)00135-8 · Cited by 698
Cited by
Models of cardiac tissue electrophysiology: Progress, challenges and open questions
Clayton, R. H., Bernus, O., Cherry, E. M., Dierckx, H., Fenton, F. H., Mirabella, L., Panfilov, A. V., Sachse, F. B., Seemann, G., & Zhang, H. (2011) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2010.05.008 · Cited by 585
Self-citationComputational models in cardiology
Niederer, S. A., Lumens, J., & Trayanova, N. A. (2019) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0104-y · Cited by 434
The openCARP simulation environment for cardiac electrophysiology
Plank, G., Loewe, A., Neic, A., Augustin, C., Huang, Y.-L., Gsell, M. A. F., Karabelas, E., Nothstein, M., Prassl, A. J., Sánchez, J., et al. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106223 · Cited by 264
Self-citationThree-dimensional cardiac computational modelling: methods, features and applications.
Lopez-Perez, A., Sebastian, R., & Ferrero, J. M. (2015) · BioMedical Engineering OnLine · doi:10.1186/s12938-015-0033-5 · Cited by 151
Carusi, A., Burrage, K., & Rodríguez, B. (2012) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01151.2011 · Cited by 102
Metadata
- Authors
- Seemann, G., Höper, C., Sachse, F. B., Dössel, O., Holden, A. V., & Zhang, H.
- Venue
- Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Publisher
- The Royal Society
- Published
- 2006-04-12
- Volume
- 364
- Issue
- 1843
- Pages
- 1465-1481
- ISSN
- 1364-503X (ISSN-L)
- 1471-2962
- OpenAlex
- W2129656446
- Cited by
- 239
- References
- 1
- FWCI
- 8.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.