The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Direct measurement of tissue blood flow and metabolism with diffuse optics
Open accessAbstract
Diffuse optics has proven useful for quantitative assessment of tissue oxy- and deoxyhaemoglobin concentrations and, more recently, for measurement of microvascular blood flow. In this paper, we focus on the flow monitoring technique: diffuse correlation spectroscopy (DCS). Representative clinical and pre-clinical studies from our laboratory illustrate the potential of DCS. Validation of DCS blood flow indices in human brain and muscle is presented. Comparison of DCS with arterial spin-labelled MRI, xenon-CT and Doppler ultrasound shows good agreement (0.50< r <0.95) over a wide range of tissue types and source detector distances, corroborating the potential of the method to measure perfusion non-invasively and in vivo at the microvasculature level. All-optical measurements of cerebral oxygen metabolism in both rat brain, following middle cerebral artery occlusion, and human brain, during functional activation, are also described. In both situations, the use of combined DCS and diffuse optical spectroscopy/near-infrared spectroscopy to monitor changes in oxygen consumption by the tissue is demonstrated. Finally, recent results spanning from gene expression-induced angiogenic response to stroke care and cancer treatment monitoring are discussed. Collectively, the research illustrates the capability of DCS to quantitatively monitor perfusion from bench to bedside, providing results that match up both with literature findings and with similar experiments performed with other techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Cited by
Diffuse correlation spectroscopy for non-invasive, micro-vascular cerebral blood flow measurement
Durduran, T., & Yodh, A. G. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.017 · Cited by 536
Self-citationModified Beer-Lambert law for blood flow
Baker, W. B., Parthasarathy, A. B., Busch, D. R., Mesquita, R. C., Greenberg, J. H., & Yodh, A. G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.004053 · Cited by 283
Self-citationCerebral Near-Infrared Spectroscopy in Adults: A Work in Progress
Ghosh, A., Elwell, C., & Smith, M. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31826dd6a6 · Cited by 277
Yücel, M. A., Selb, J., Boas, D. A., Cash, S. S., & Cooper, R. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.054 · Cited by 86
Metadata
- Authors
- Mesquita, R. C., Durduran, T., Yu, G., Buckley, E. M., Kim, M. N., Zhou, C., Choe, R., Sunar, U., & Yodh, A. G.
- Venue
- Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Publisher
- The Royal Society
- Published
- 2011-11-28
- Volume
- 369
- Issue
- 1955
- Pages
- 4390-4406
- ISSN
- 1364-503X (ISSN-L)
- 1471-2962
- OpenAlex
- W2129154930
- Cited by
- 195
- References
- 1
- FWCI
- 10.80
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct measurement of tissue blood flow and metabolism with diffuse optics. https://app.cochat.ai/papers/10.1098/rsta.2011.0232
- The paper
- Mesquita, R. C., Durduran, T., Yu, G., Buckley, E. M., Kim, M. N., Zhou, C., Choe, R., Sunar, U., & Yodh, A. G. (2011). Direct measurement of tissue blood flow and metabolism with diffuse optics. Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences. https://doi.org/10.1098/rsta.2011.0232
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.