Mechanism of persistent infection associated with peritoneal implants
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The ability of rabbits to clear an intraperitoneal injection of Pseudomonas aeruginosa in the presence or absence of a surgically implanted peritoneal device was investigated. Sham-operated rabbits without an implant eliminated a P. aeruginosa challenge of 5 x 10(6) cfu/ml; lavage fluid and peritoneal tissues became culture-negative within 96 h. However, peritonitis developed in rabbits that were given the same number of bacteria in the presence of an implant; high bacterial counts were recovered from the lavage fluid and the device itself. Scanning and transmission electronmicroscopy revealed bacterial biofilms on the surface of the device. Insertion of pre-colonised devices demonstrated a rapid multiplication of sessile organisms within the resulting bacterial biofilm. Counts reached a plateau of about 1 x 10(7) cfu/cm2 of Silastic by day 16 and fluctuated around this level until the end of the study. Pre-immunisation with formalin-killed whole cells of P. aeruginosa did not reduce this bacterial growth despite high levels of specific IgG. The results confirm the failure of peritoneal defences to clear an infection in the presence of an implant following either challenge with planktonic bacteria or insertion of a pre-colonised device, and demonstrate the rapid development of bacterial biofilms on the surface of the implant which appear to protect the bacteria from host defences, even when primed by pre-immunisation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marrie, T. J., & Costerton, J. W. (1984) · Journal of Clinical Microbiology · doi:10.1128/jcm.19.5.687-693.1984 · Cited by 327
Self-citation
Cited by
Bacterial Biofilms: A Common Cause of Persistent Infections
Costerton, J. W., Stewart, P. S., & Greenberg, E. P. (1999) · Science · doi:10.1126/science.284.5418.1318 · Cited by 12,167
Self-citationBiofilms: Survival Mechanisms of Clinically Relevant Microorganisms
Donlan, R. M., & Costerton, J. W. (2002) · Clinical Microbiology Reviews · doi:10.1128/cmr.15.2.167-193.2002 · Cited by 6,644
“(211) used a rabbit model to show that bacterial growth within a biofilm on an implanted peritoneal device was unaffected by the vaccinated animal’s immune system (in terms of phagocytosis).”
MethodSelf-citationBiofilms: Microbial Life on Surfaces
Donlan, R. M. (2002) · Emerging Infectious Diseases · doi:10.3201/eid0809.020063 · Cited by 4,145
Anderl, J. N., Franklin, M. J., & Stewart, P. S. (2000) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.44.7.1818-1824.2000 · Cited by 958
“Medical implants are particularly susceptible to biofilm formation because immune responses are markedly reduced in the proximity of foreign bodies (7, 42).”
BackgroundEffects of biofilm structures on oxygen distribution and mass transport
de Beer, D., Stoodley, P., Roe, F., & Lewandowski, Z. (1994) · Biotechnology and Bioengineering · doi:10.1002/bit.260431118 · Cited by 876
Metadata
- Authors
- Ward, K. H., Olson, M. E., Lam, K., & Costerton, J. W.
- Venue
- Journal of Medical Microbiology
- Publisher
- Microbiology Society
- Published
- 1992-06-01
- Volume
- 36
- Issue
- 6
- Pages
- 406-413
- ISSN
- 0022-2615 (ISSN-L)
- 1473-5644
- OpenAlex
- W2043110296
- Cited by
- 88
- References
- 1
- FWCI
- 1.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanism of persistent infection associated with peritoneal implants. https://app.cochat.ai/papers/10.1099/00222615-36-6-406
- The paper
- Ward, K. H., Olson, M. E., Lam, K., & Costerton, J. W. (1992). Mechanism of persistent infection associated with peritoneal implants. Journal of Medical Microbiology. https://doi.org/10.1099/00222615-36-6-406
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.