The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Index switching causes “spreading-of-signal” among multiplexed samples in Illumina HiSeq 4000 DNA sequencing
Open accessAbstract
Illumina-based next generation sequencing (NGS) has accelerated biomedical discovery through its ability to generate thousands of gigabases of sequencing output per run at a fraction of the time and cost of conventional technologies. The process typically involves four basic steps: library preparation, cluster generation, sequencing, and data analysis. In 2015, a new chemistry of cluster generation was introduced in the newer Illumina machines (HiSeq 3000/4000/X Ten) called exclusion amplification (ExAmp), which was a fundamental shift from the earlier method of random cluster generation by bridge amplification on a non-patterned flow cell. The ExAmp chemistry, in conjunction with patterned flow cells containing nanowells at fixed locations, increases cluster density on the flow cell, thereby reducing the cost per run. It also increases sequence read quality, especially for longer read lengths (up to 150 base pairs). This advance has been widely adopted for genome sequencing because greater sequencing depth can be achieved for lower cost without compromising the quality of longer reads. We show that this promising chemistry is problematic, however, when multiplexing samples. We discovered that up to 5-10% of sequencing reads (or signals) are incorrectly assigned from a given sample to other samples in a multiplexed pool. We provide evidence that this “spreading-of-signals” arises from low levels of free index primers present in the pool. These index primers can prime pooled library fragments at random via complementary 3’ ends, and get extended by DNA polymerase, creating a new library molecule with a new index before binding to the patterned flow cell to generate a cluster for sequencing. This causes the resulting read from that cluster to be assigned to a different sample, causing the spread of signals within multiplexed samples. We show that low levels of free index primers persist after the most common library purification procedure recommended by Illumina, and that the amount of signal spreading among samples is proportional to the level of free index primer present in the library pool. This artifact causes homogenization and misclassification of cells in single cell RNA-seq experiments. Therefore, all data generated in this way must now be carefully re-examined to ensure that “spreading-of-signals” has not compromised data analysis and conclusions. Re-sequencing samples using an older technology that uses conventional bridge amplification for cluster generation, or improved library cleanup strategies to remove free index primers, can minimize or eliminate this signal spreading artifact.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Full-length RNA-seq from single cells using Smart-seq2
Picelli, S., Faridani, O. R., Björklund, Å. K., Winberg, G., Sagasser, S., & Sandberg, R. (2014) · Nature Protocols · doi:10.1038/nprot.2014.006 · Cited by 4,137
Hoxb5 marks long-term haematopoietic stem cells and reveals a homogenous perivascular niche
Chen, J. Y., Miyanishi, M., Wang, S. K., Yamazaki, S., Sinha, R., Kao, K. S., Seita, J., Sahoo, D., Nakauchi, H., & Weissman, I. L. (2016) · Nature · doi:10.1038/nature16943 · Cited by 345
Self-citation
Cited by
Unicycler: Resolving bacterial genome assemblies from short and long sequencing reads
Wick, R. R., Judd, L. M., Gorrie, C. L., & Holt, K. E. (2017) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1005595 · Cited by 8,653
Wound Healing: A Cellular Perspective
Rodrigues, M., Kosaric, N., Bonham, C. A., & Gurtner, G. C. (2019) · Physiological Reviews · doi:10.1152/physrev.00067.2017 · Cited by 3,013
Shotgun metagenomics, from sampling to analysis
Quince, C., Walker, A. W., Simpson, J. T., Loman, N. J., & Segata, N. (2017) · Nature Biotechnology · doi:10.1038/nbt.3935 · Cited by 2,202
Clinical Metagenomic Next-Generation Sequencing for Pathogen Detection
Gu, W., Miller, S., & Chiu, C. Y. (2019) · Annual Review of Pathology: Mechanisms of Disease · doi:10.1146/annurev-pathmechdis-012418-012751 · Cited by 1,458
The Short Chain Fatty Acid Butyrate Imprints an Antimicrobial Program in Macrophages
Schulthess, J., Pandey, S., Capitani, M., Rue-Albrecht, K. C., Arnold, I., Franchini, F., Chomka, A., Ilott, N. E., Johnston, D. G. W., Pires, E., et al. (2019) · Immunity · doi:10.1016/j.immuni.2018.12.018 · Cited by 1,037
Metadata
- Authors
- Sinha, R., Stanley, G., Gulati, G. S., Ezran, C., Travaglini, K. J., Wei, E., Chan, C. K. F., Nabhan, A. N., Su, T., Morganti, R. M., Conley, S. D., Chaib, H., Red-Horse, K., Longaker, M. T., Snyder, M. P., Krasnow, M. A., & Weissman, I. L.
- Venue
- bioRxiv (Cold Spring Harbor Laboratory)
- Publisher
- openRxiv
- Published
- 2017-04-09
- OpenAlex
- W2606200318
- Cited by
- 209
- References
- 2
- Type
- posted content
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Index switching causes “spreading-of-signal” among multiplexed samples in Illumina HiSeq 4000 DNA sequencing. https://app.cochat.ai/papers/10.1101/125724
- The paper
- Sinha, R., Stanley, G., Gulati, G. S., Ezran, C., Travaglini, K. J., Wei, E., Chan, C. K. F., Nabhan, A. N., Su, T., Morganti, R. M., Conley, S. D., Chaib, H., Red-Horse, K., Longaker, M. T., Snyder, M. P., Krasnow, M. A., & Weissman, I. L. (2017). Index switching causes “spreading-of-signal” among multiplexed samples in Illumina HiSeq 4000 DNA sequencing. bioRxiv (Cold Spring Harbor Laboratory). https://doi.org/10.1101/125724
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.