Automated sample preparation for high-throughput single-cell proteomics
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
A major limitation to applying quantitative LC-MS/MS proteomics to small samples, such as single cells, are the losses incured during sample cleanup. To relieve this limitation, we developed a Minimal ProteOmic sample Preparation (mPOP) method for culture-grown mammalian cells. mPOP obviates cleanup and thus eliminates cleanup-related losses while expediting sample preparation and simplifying its automation. Bulk SILAC samples processed by mPOP or by conventional urea-based methods indicated that mPOP results in complete cell lysis and accurate relative quantification. We integrated mPOP lysis with the Single Cell ProtEomics by Mass Spectrometry (SCoPE-MS) sample preparation, and benchmarked the quantification of such samples on a Q-exactive instrument. The results demonstrate low noise and high technical reproducibility. Then, we FACS sorted single U-937, HEK-293, and mouse ES cells into 96-well plates and analyzed them by automated mPOP and SCoPE-MS. The quantified proteins enabled separating the single cells by cell-type and cell-division-cycle phase.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rappsilber, J., Mann, M., & Ishihama, Y. (2007) · Nature Protocols · doi:10.1038/nprot.2007.261 · Cited by 4,641
Kulak, N. A., Pichler, G., Paron, I., Nagaraj, N., & Mann, M. (2014) · Nature Methods · doi:10.1038/nmeth.2834 · Cited by 1,719
Budnik, B., Levy, E., Harmange, G., & Slavov, N. (2018) · Genome Biology · doi:10.1186/s13059-018-1547-5 · Cited by 832
Self-citationZhu, Y., Piehowski, P. D., Zhao, R., Chen, J., Shen, Y., Moore, R. J., Shukla, A. K., Petyuk, V. A., Campbell-Thompson, M., Mathews, C. E., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-03367-w · Cited by 587
Cited by
Budnik, B., Levy, E., Harmange, G., & Slavov, N. (2018) · Genome Biology · doi:10.1186/s13059-018-1547-5 · Cited by 832
“These approaches include reduced lysis volume and thus protein loss [50],”
BackgroundSelf-citationSingle-cell proteomic and transcriptomic analysis of macrophage heterogeneity using SCoPE2
Specht, H., Emmott, E., Petelski, A. A., Huffman, R. G., Perlman, D. H., Serra, M., Kharchenko, P., Koller, A., & Slavov, N. (2021) · Genome Biology · doi:10.1186/s13059-021-02267-5 · Cited by 493
Self-citationBeyond mass spectrometry, the next step in proteomics
Timp, W., & Timp, G. (2020) · Science Advances · doi:10.1126/sciadv.aax8978 · Cited by 302
Increasing the throughput of sensitive proteomics by plexDIA
Derks, J., Leduc, A., Wallmann, G., Huffman, R. G., Willetts, M., Khan, S., Specht, H., Ralser, M., Demichev, V., & Slavov, N. (2023) · Nature Biotechnology · doi:10.1038/s41587-022-01389-w · Cited by 232
Self-citationMultiplexed single-cell proteomics using SCoPE2
Petelski, A. A., Emmott, E., Leduc, A., Huffman, R. G., Specht, H., Perlman, D. H., & Slavov, N. (2021) · Nature Protocols · doi:10.1038/s41596-021-00616-z · Cited by 228
Self-citation
Metadata
- Authors
- Specht, H., Harmange, G., Perlman, D. H., Emmott, E., Niziolek, Z., Budnik, B., & Slavov, N.
- Venue
- bioRxiv (Cold Spring Harbor Laboratory)
- Publisher
- openRxiv
- Published
- 2018-08-25
- OpenAlex
- W2888464907
- Cited by
- 75
- References
- 4
- Type
- posted content
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated sample preparation for high-throughput single-cell proteomics. https://app.cochat.ai/papers/10.1101/399774
- The paper
- Specht, H., Harmange, G., Perlman, D. H., Emmott, E., Niziolek, Z., Budnik, B., & Slavov, N. (2018). Automated sample preparation for high-throughput single-cell proteomics. bioRxiv (Cold Spring Harbor Laboratory). https://doi.org/10.1101/399774
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.