A First-Order Design Requirement to Prevent Edema in Mechanical Counter-Pressure Space Suit Garments
Open accessThe DOI matches its Crossref record; 21 of the 22 references it cites were found in a registry or an index; 1 of the 23 sources its claims cite were checked for support.
Abstract
Introduction Mechanical counter-pressure (MCP) space suits may provide enhanced mobility relative to gas-pressure space suits. One challenge to realizing operational MCP suits is the potential for edema caused by spatial variations in the applied body-surface pressure (dP). We determined a first-order requirement for these variations. Methods Darcy’s law relates volume flux, of fluid from capillaries to the interstitial space, to transmural hydraulic and osmotic pressure differences. Albumin and fibrinogen levels determine, to first order, the capillary oncotic pressure (COP). We estimated dP, neglecting hydrostatic pressure differences, by equating the volume flux under MCP and under normal with the volume flux under abnormal variations in COP; then we compared these estimates to results from MCP garment studies. Results Normal COP varies from 20-32 mm Hg; with constant hydraulic conductivity, dP≈12 mm Hg. In nephrotic syndrome, COP may drop to 11 mm Hg, yielding dP≈15 mm Hg relative to mid-normal COP. Previous studies found dP max =151 mm Hg (MCP glove; finger and hand dorsum relative to palm), dP max =51 mm Hg (MCP arm; finger, hand dorsum, and wrist relative to arm), and dP=52, 90 and 239 mm Hg (three MCP lower leg garments). Conclusions MCP garments with dP max ≤12 mm Hg are unlikely to produce edema or restrict capillary blood flow; however, garments with dP max >12 mm Hg will not necessarily produce edema. For example, the hydrostatic pressure gradient at the feet in 1g can range from 70-90 mm Hg. Current garment prototypes do not meet our conservative design requirement.
Overview
CoChat Summary
TL;DR
The paper derives a conservative first-order design requirement that spatial variations in mechanical counter-pressure (MCP) suit pressure should be ≤12 mm Hg to avoid edema under chronic wear. It finds that existing MCP garment prototypes have much larger pressure variations and fail this criterion by a factor of 4–20.
Key findings
- Normal capillary oncotic pressure varies from approximately 20–32 mm Hg; with constant hydraulic conductivity, the equivalent allowable spatial variation in MCP body-surface pressure is dP≈12 mm Hg. In nephrotic syndrome, COP may drop to 11 mm Hg, yielding dP≈15 mm Hg relative to mid-normal COP.
- Reported MCP garment spatial pressure variations were much larger: dPmax=151 mm Hg for an MCP glove, dPmax=51 mm Hg for an MCP arm, and dP=52, 90, and 239 mm Hg for three MCP lower leg garments.
- MCP garments with dPmax ≤12 mm Hg are unlikely to produce edema or restrict capillary blood flow; however, garments with dPmax >12 mm Hg will not necessarily produce edema, since the hydrostatic pressure gradient at the feet in 1g can range from 70–90 mm Hg.
- Skin tension contributed on the order of 5 mm Hg to interstitial pressure in the thigh region (Table I: dorsal thigh 4.9 mm Hg, volar thigh 4.8 mm Hg).
Methods
- Used Darcy’s law, known as the Starling hypothesis when applied across capillary endothelium, to construct a one-dimensional microcirculation model relating volume flux to transmural hydraulic and oncotic pressure differences. Capillary oncotic pressure was predicted from albumin and fibrinogen concentrations; interstitial oncotic pressure was taken as 16 mm Hg, reflection coefficient as 1, and capillary hydraulic pressure gradient as 30–10 mm Hg except in congestive heart failure.
- Estimated allowable MCP pressure variation by equating volume flux under MCP wear with volume flux under abnormal variations in capillary oncotic pressure, then compared these estimates to pressure data from all known past MCP garment studies as of 2005 plus unpublished data from garments tested on a non-compliant three-dimensional leg model.
- Estimated skin tension contribution by treating a body segment as an irregular cylinder and using dorsal and volar thigh skin principal stress data from Reihsner & Menzel (1996), with thigh circumference from NASA standards.
Limitations
- The paper states the capillary model is entirely passive and its flow-limitation model based on capillary closure is a gross approximation; the lack of feedback regulation causes the model to over-predict changes in volume flux due to changes in transmural hydraulic pressure.
- The paper states the MCP pressure data used were means, so actual spatial variability is likely greater than reported; Tekscan sensor noise from bending or bunching may artificially increase measured variability, and the non-compliant three-dimensional leg model may elevate reported spatial variations by not deforming elastically and by adding sensor bending.
- The paper states that compatibility of MCP with longer-term fluid balance is unknown, as are allowable variations in body-surface pressure; variable tissue resistance to edema cannot be determined without longer-duration tests of up-to-date MCP garments.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
1 Valid · 5 Not valid · 18 Not checked · 24 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Fauschald et al. (1985) measured subcutaneous interstitial oncotic pressure to be 15.8±2.7 mm Hg in ten healthy humans [7]”
§ A First-Order Design Requirement to Prevent Edema in Mechanical Counter-Pressure Space Suit Garments > METHODS
What the sources say
- Partly supportedcites [7] 7. Fauchald P, Norseth J, and Jervell J. Transcapillary colloid osmotic gradient, plasma volume and interstitial fluid volume in long-term Type 1 (insulin-dependent) diabetes. Diabetologia 1985; 28:269-73. sourceExperimental — accuracy not yet measured
Table 2 (p. 3) reports an interstitial colloid osmotic pressure of 15.8 ± 2.7 mmHg in normal subjects, and the Methods (p. 2) say the fluid was collected from subcutaneous tissue. But Table 2 and the Normal subjects section (p. 1) specify 16 healthy subjects, not ten; ten was the number of diabetic patients. (LLM, conf=0.94)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The - dP values for MCP garments are, on average, a factor of 3-6 times greater in magnitude than this range (Table III).”
§ A First-Order Design Requirement to Prevent Edema in Mechanical Counter-Pressure Space Suit Garments > RESULTS
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“For example, in the normal condition volume flux is small and positive, consistent with removal of fluid from the interstitial space by the lymphatic system.”
§ A First-Order Design Requirement to Prevent Edema in Mechanical Counter-Pressure Space Suit Garments > DISCUSSION
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The + dP values for MCP garments are, on average, a factor of approximately 13 times greater in magnitude than the equivalent + dP resulting from normal variations in capillary oncotic pressure.”
§ A First-Order Design Requirement to Prevent Edema in Mechanical Counter-Pressure Space Suit Garments > RESULTS
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Current garment prototypes do not meet our conservative design requirement.”
- Also stated in: § MCP Garments: · plain
“Garment prototypes as of this analysis (~2005) fail to meet this design requirement by a factor of 4-20”
§ A First-Order Design Requirement to Prevent Edema in Mechanical Counter-Pressure Space Suit Garments > Abstract
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § MCP Garments: · plain
19 more claims
Create a free account to see all 48 claims and every source verdict.
- Borderline: one of the tests for a substantial claim is unclear. 2
- It may state two separate claims as one. 17
- Probably not a substantial claim. 7
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ A First-Order Design Requirement to Prevent Edema in Mechanical Counter-Pressure Space Suit Garments > Abstract
“dP max =51 mm Hg (MCP arm; finger, hand dorsum, and wrist relative to arm)”
§ A First-Order Design Requirement to Prevent Edema in Mechanical Counter-Pressure Space Suit Garments > RESULTS
“MCP Arm Locations: F, W, D, FA, UA * 78 23 55 Tanaka et al. (2003)”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ A First-Order Design Requirement to Prevent Edema in Mechanical Counter-Pressure Space Suit Garments > Abstract
“dP max =151 mm Hg (MCP glove; finger and hand dorsum relative to palm)”
§ A First-Order Design Requirement to Prevent Edema in Mechanical Counter-Pressure Space Suit Garments > RESULTS
“MCP Glove Locations: F, D, P * 74 -78 153 Tanaka et al. (2002)”
Citations
Cites
On the anatomy and physiology of the skin
Langer, K. (1978) · British Journal of Plastic Surgery · doi:10.1016/0007-1226(78)90003-6 · Cited by 296 · cited 1×
“Because q is a strong function of body location, related to the Langer lines [14], we treated q as a uniform random variable with range p q 2 0 < £ .”
MethodParker, J. F., & West, V. R. (1972) · Cited by 233
Zur Anatomie und Physiologie der Haut. I. Über die Spaltbarkeit der Cutis
Langer, K. H. (1861) · Biodiversity Heritage Library (Smithsonian Institution) · Cited by 157
Influence of compression hosiery on physiological responses to standing fatigue in women
KRAEMER, W. J., VOLEK, J. S., BUSH, J. A., GOTSHALK, L. A., WAGNER, P. R., G??MEZ, A. L., ZATSIORSKY, V. M., DUZRTE, M., RATAMESS, N. A., MAZZETTI, S. A., et al. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200011000-00006 · Cited by 118
Albumin turnover: experimental approach and its application in health and renal diseases
Prinsen, B. H. C. M. T., & de Sain-van der Velden, M. G. M. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.005 · Cited by 77 · cited 1×
“Because synthesis of Albumin and Fibrinogen is known to co-vary [18], the normal c p range was estimated using high normal ( = Fib 0.”
MethodVollmar, B., Westermann, S., & Menger, M. D. (1999) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-199901000-00015 · Cited by 68 · cited 1×
“Vollmar et al. (1999) applied external pressure to skin folds of Syrian golden hamsters as a model of compartment syndrome and determined the applied pressure required for blood flow to cease in different elements of the microcirculation using intravital fluorescence microscopy [22].”
MethodThe importance of plasma protein for blood volume and blood pressure homeostasis
Koomans, H. A., Braam, B., Geers, A. B., Roos, J. C., & Dorhout Mees, E. J. (1986) · Kidney International · doi:10.1038/ki.1986.248 · Cited by 52
Fauchald, P., Norseth, J., & Jervell, J. (1985) · Diabetologia · doi:10.1007/bf00271683 · Cited by 47 · cited 1×
“7 mm Hg in ten healthy humans [7]; we have taken 16 = i p mm Hg except where otherwise indicated.”
On the Orthogonal Anisotropy of Human Skin as a Function of Anatomical Region
Reihsner, R., & Menzel, E. J. (1996) · Connective Tissue Research · doi:10.3109/03008209609021498 · Cited by 35 · cited 4×
“Reihsner & Menzel (1996) reported skin principle stresses ( I s , II s ) in newtons [19]; the stresses reported here were computed using the 30 mm sample diameter and skin thickness t .”
BackgroundMethodInfluentialThe space activity suit: an elastic leotard for extravehicular activity.
Webb, P. W. (1968) · PubMed · Cited by 31
Research works printed but not linked: 4
- 2. Berne RM, Levy MN, eds. Physiology, 4 th Ed. St. Louis: Mosby; 1998.
- 4. Clapp M. Design and Testing of an Advanced Spacesuit Glove. Cambridge, MA: Massachusetts Institute of Technology, Center for Space Research, Space Systems Laboratory; 1983. Report No: 17-83.
- 5. Crandall SH, Dahl NC, Lardner TJ. An Introduction to the Mechanics of Solids, 2nd Ed. New York: McGraw-Hill; 1978.
- 15. Man-Systems Integration Standards, Vol. 1, Rev. B. Washington, DC: National Aeronautics and Space Administration; 1995. Report No.: NASA-STD-3000.
Cited by
Soft Exoskeleton Knee Prototype for Advanced Space Suits and Planetary Exploration
Porter, A., Marchesini, B., Potryasilova, I., Rossetto, E., & Newman, D. J. (2020) · IEEE Aerospace Conference (AERO) · doi:10.1109/aero47225.2020.9172373 · Cited by 19
“Further details concerning the physiological significance of these criteria can be found in [22].”
Background
Metadata
- Authors
- Carr, C. E., & Treviño, L.
- Affiliations
- Massachusetts Institute of Technology (US)
- Corresponding author
- Carr, Christopher E.
- ORCID
- Carr, Christopher E.
- Venue
- bioRxiv
- Publisher
- openRxiv
- Published
- 2019-05-10
- OpenAlex
- W2944027243
- Semantic Scholar
- 0c257ab8844b9f521fa6e2f04b6b2f1171912920
- Cited by
- 1
- References
- 22
- Citations by year
- 2020: 1
- Type
- posted content
- Language
- en
- Open access
- green
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion, cc-by-nc-nd)
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Space Exploration and Technology
- Health Sciences › Medicine › Physiology (medical) › Spaceflight effects on biology
- Physical Sciences › Materials Science › Polymers and Plastics › Textile materials and evaluations
- Keywords
- edema prevention, Darcy's law, nephrotic syndrome, hydraulic conductivity, capillary blood flow
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.