CoChat

Systematic evaluation of variability in ChIP-chip experiments using predefined DNA targets

Open access
Johnson, David S., Li, Wei, Gordon, D. Benjamin, Bhattacharjee, Arindam, Curry, Bo, Ghosh, Jayati, Brizuela, Leonardo, Carroll, Jason S., Brown, Myles, Flicek, Paul, Koch, Christoph M., Dunham, Ian, Bieda, Mark, Xu, Xiaoqin, Farnham, Peggy J., Kapranov, Philipp, Nix, David A., Gingeras, Thomas R., Zhang, Xinmin, Holster, Heather, Jiang, Nan, Green, Roland D., Song, Jun S., McCuine, Scott A., Anton, Elizabeth, Nguyen, Loan, Trinklein, Nathan D., Ye, Zhen, Ching, Keith, Hawkins, David, Ren, Bing, Scacheri, Peter C., Rozowsky, Joel, Karpikov, Alexander, Euskirchen, Ghia, Weissman, Sherman, Gerstein, Mark, Snyder, Michael, Yang, Annie, Moqtaderi, Zarmik, Hirsch, Heather, Shulha, Hennady P., Fu, Yutao, Weng, Zhiping, Struhl, Kevin, Myers, Richard M., Lieb, Jason D., Liu, X. Shirley · 2008 · Genome Research
Cited by 130

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

The most widely used method for detecting genome-wide protein–DNA interactions is chromatin immunoprecipitation on tiling microarrays, commonly known as ChIP-chip. Here, we conducted the first objective analysis of tiling array platforms, amplification procedures, and signal detection algorithms in a simulated ChIP-chip experiment. Mixtures of human genomic DNA and “spike-ins” comprised of nearly 100 human sequences at various concentrations were hybridized to four tiling array platforms by eight independent groups. Blind to the number of spike-ins, their locations, and the range of concentrations, each group made predictions of the spike-in locations. We found that microarray platform choice is not the primary determinant of overall performance. In fact, variation in performance between labs, protocols, and algorithms within the same array platform was greater than the variation in performance between array platforms. However, each array platform had unique performance characteristics that varied with tiling resolution and the number of replicates, which have implications for cost versus detection power. Long oligonucleotide arrays were slightly more sensitive at detecting very low enrichment. On all platforms, simple sequence repeats and genome redundancy tended to result in false positives. LM-PCR and WGA, the most popular sample amplification techniques, reproduced relative enrichment levels with high fidelity. Performance among signal detection algorithms was heavily dependent on array platform. The spike-in DNA samples and the data presented here provide a stable benchmark against which future ChIP platforms, protocol improvements, and analysis methods can be evaluated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1101/gr.7080508

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Johnson, D. S., Li, W., Gordon, D. B., Bhattacharjee, A., Curry, B., Ghosh, J., Brizuela, L., Carroll, J. S., Brown, M., Flicek, P., Koch, C. M., Dunham, I., Bieda, M., Xu, X., Farnham, P. J., Kapranov, P., Nix, D. A., Gingeras, T. R., Zhang, X., Holster, H., Jiang, N., Green, R. D., Song, J. S., McCuine, S. A., Anton, E., Nguyen, L., Trinklein, N. D., Ye, Z., Ching, K., Hawkins, D., Ren, B., Scacheri, P. C., Rozowsky, J., Karpikov, A., Euskirchen, G., Weissman, S., Gerstein, M., Snyder, M., Yang, A., Moqtaderi, Z., Hirsch, H., Shulha, H. P., Fu, Y., Weng, Z., Struhl, K., Myers, R. M., Lieb, J. D., & Liu, X. S.
Venue
Genome Research
Published
2008-02-07
Volume
18
Issue
3
Pages
393-403
ISSN
1088-9051 (ISSN-L)
OpenAlex
W4299429246
Cited by
130
References
6
Type
posted content
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.