Abstract
Liver specific contrast media (LSCM) can be subdivided according to different modalities of hepatic distribution: exclusive distribution to the hepatocellular compartment can be obtained using CM which accumulate within the hepatocytes after slow infusion; other CM demonstrate combined perfusion and hepatocyte-selective properties, with an initial distribution to the vascular-interstitial compartment (in an analogous manner to that of the conventional extracellular CM), thereafter, a fraction of the injected dose is taken up into the hepatocytes causing an increase in the signal intensity of the hepatic tissue. The use of the superparamagnetic effect of iron oxide particles is based on distribution in the reticuloendothelial system (RES), usually well represented in the normal parenchyma as well as in benign hepatocellular lesions, and absent in most malignant lesions. It is necessary to have an in-depth knowledge of either the biological and histological characteristics of focal liver lesions (FLL) or the enhancement mechanism of LSCM to gain significant accuracy in the differential diagnosis of FLL. Dynamic contrast-enhanced MRI is an important tool in the identification and characterization of FLL. With LSCM it is possible to differentiate benign from malignant lesions and hepatocellular lesions from non hepatocellular lesions with high accuracy. To understand the contrast behaviour after injection of LSCM it is necessary to correlate the contrast enhancement with both the biological and histological findings of FLL.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Applications and potential toxicity of magnetic iron oxide nanoparticles
Liu, G., Gao, J., Ai, H., & Chen, X. (2013) · Small · doi:10.1002/smll.201201531 · Cited by 570
Anticancer nanomedicine and tumor vascular permeability; Where is the missing link?
Taurin, S., Nehoff, H., & Greish, K. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.07.013 · Cited by 309
Cell Uptake and in Vitro Toxicity of Magnetic Nanoparticles Suitable for Drug Delivery
Häfeli, U. O., Riffle, J. S., Harris-Shekhawat, L., Carmichael-Baranauskas, A., Mark, F., Dailey, J. P., & Bardenstein, D. (2009) · Molecular Pharmaceutics · doi:10.1021/mp900083m · Cited by 277
Nanoparticles for Imaging: top or Flop?
Kiessling, F., Mertens, M. E., Grimm, J., & Lammers, T. (2014) · Radiology · doi:10.1148/radiol.14131520 · Cited by 228
Magnetic nanoparticles as targeted delivery systems in oncology
Prijic, S., & Sersa, G. (2011) · Radiology and Oncology · doi:10.2478/v10019-011-0001-z · Cited by 203
Metadata
- Authors
- Morana, G.
- Venue
- Cancer Imaging
- Publisher
- E-MED LTD
- Published
- 2007
- Volume
- 7
- Issue
- Special Issue A
- Pages
- S24-S27
- ISSN
- 1470-7330 (ISSN-L)
- OpenAlex
- W2004150969
- Cited by
- 61
- References
- 0
- FWCI
- 2.28
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Contrast agents for hepatic MRI. https://app.cochat.ai/papers/10.1102/1470-7330.2007.9001
- The paper
- Morana, G. (2007). Contrast agents for hepatic MRI. Cancer Imaging. https://doi.org/10.1102/1470-7330.2007.9001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.