Quantitative 177 Lu SPECT (QSPECT) imaging using a commercially available SPECT/CT system
Open accessThe DOI matches its Crossref record.
Abstract
PURPOSE: The combination of single photon emission computed tomography (SPECT) and computer tomography (CT) that incorporates iterative reconstruction algorithms with attenuation and scatter correction should facilitate accurate non-invasive quantitative imaging. Quantitative SPECT (QSPECT) may improve diagnostic ability and could be useful for many applications including dosimetry assessment. Using (177)Lu, we developed a QSPECT method using a commercially available SPECT/CT system. METHODS: Serial SPECT of (177)Lu sources (89-12,400 MBq) were acquired with multiple contiguous energy windows along with a co-registered CT, and were reconstructed using an iterative algorithm with attenuation and scatter correction. Camera sensitivity (based on reconstructed SPECT count rate) and dead-time (based on wide-energy spectrum count rate) were resolved by non-linear curve fit. Utilizing these parameters, a SPECT dataset can be converted to a QSPECT dataset allowing quantitation in Becquerels per cubic centimetre or standardized uptake value (SUV). Validation QSPECT/CT studies were performed on a (177)Lu cylindrical phantom (7 studies) and on 5 patients (6 studies) who were administered a therapeutic dose of [(177)Lu]octreotate. RESULTS: The QSPECT sensitivity was 1.08 x 10(-5) ± 0.02 x 10(-5) s(-1) Bq(-1). The paralyzing dead-time constant was 0.78 ± 0.03 µs. The measured total activity with QSPECT deviated from the calibrated activity by 5.6 ± 1.9% and 2.6 ± 1.8%, respectively, in phantom and patients. Dead-time count loss up to 11.7% was observed in patient studies. CONCLUSION: QSPECT has high accuracy both in our phantom model and in clinical practice following [(177)Lu]octreotate therapy. This has the potential to yield more accurate dosimetry estimates than planar imaging and facilitate therapeutic response assessment. Validating this method with other radionuclides could open the way for many other research and clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hofman, M. S., Violet, J., Hicks, R. J., Ferdinandus, J., Thang, S. P., Akhurst, T., Iravani, A., Kong, G., Ravi Kumar, A., Murphy, D. G., et al. (2018) · The Lancet Oncology · doi:10.1016/s1470-2045(18)30198-0 · Cited by 1,174
Self-citationViolet, J., Jackson, P., Ferdinandus, J., Sandhu, S., Akhurst, T., Iravani, A., Kong, G., Kumar, A. R., Thang, S. P., Eu, P., et al. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.219352 · Cited by 504
Self-citationTaïeb, D., Hicks, R. J., Hindié, E., Guillet, B. A., Avram, A., Ghedini, P., Timmers, H. J., Scott, A. T., Elojeimy, S., Rubello, D., et al. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04398-1 · Cited by 403
Self-citationLjungberg, M., Celler, A., Konijnenberg, M. W., Eckerman, K. F., Dewaraja, Y. K., & Sjögreen-Gleisner, K. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.159012 · Cited by 369
Hicks, R. J., Kwekkeboom, D. J., Krenning, E., Bodei, L., Grozinsky-Glasberg, S., Arnold, R., Borbath, I., Cwikla, J., Toumpanakis, C., Kaltsas, G., et al. (2017) · Neuroendocrinology · doi:10.1159/000475526 · Cited by 336
Self-citation
Metadata
- Authors
- Beauregard, J.-M., Hofman, M. S., Pereira, J. M., Eu, P., & Hicks, R. J.
- Venue
- Cancer Imaging
- Publisher
- E-MED LTD
- Published
- 2011
- Volume
- 11
- Issue
- 1
- Pages
- 56-66
- ISSN
- 1470-7330 (ISSN-L)
- OpenAlex
- W2080677976
- Cited by
- 148
- References
- 0
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative 177 Lu SPECT (QSPECT) imaging using a commercially available SPECT/CT system. https://app.cochat.ai/papers/10.1102/1470-7330.2011.0012
- The paper
- Beauregard, J.-M., Hofman, M. S., Pereira, J. M., Eu, P., & Hicks, R. J. (2011). Quantitative 177 Lu SPECT (QSPECT) imaging using a commercially available SPECT/CT system. Cancer Imaging. https://doi.org/10.1102/1470-7330.2011.0012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.