Quantifying tumour heterogeneity with CT
Open accessThe DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
Heterogeneity is a key feature of malignancy associated with adverse tumour biology. Quantifying heterogeneity could provide a useful non-invasive imaging biomarker. Heterogeneity on computed tomography (CT) can be quantified using texture analysis which extracts spatial information from CT images (unenhanced, contrast-enhanced and derived images such as CT perfusion) that may not be perceptible to the naked eye. The main components of texture analysis can be categorized into image transformation and quantification. Image transformation filters the conventional image into its basic components (spatial, frequency, etc.) to produce derived subimages. Texture quantification techniques include structural-, model- (fractal dimensions), statistical- and frequency-based methods. The underlying tumour biology that CT texture analysis may reflect includes (but is not limited to) tumour hypoxia and angiogenesis. Emerging studies show that CT texture analysis has the potential to be a useful adjunct in clinical oncologic imaging, providing important information about tumour characterization, prognosis and treatment prediction and response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886 · cited 2×
“[32] Haralick RM, Shanmugam K, Dinstein I.”
BackgroundTumor angiogenesis: therapeutic implications
Sherwood, L. M., Parris, E. E., & Folkman, J. (1971) · New England Journal of Medicine · doi:10.1056/nejm197111182852108 · Cited by 10,187
Intratumor Heterogeneity and Branched Evolution Revealed by Multiregion Sequencing
Gerlinger, M., Rowan, A. J., Horswell, S., Larkin, J., Endesfelder, D., Gronroos, E., Martinez, P., Matthews, N., Stewart, A., Tarpey, P., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1113205 · Cited by 7,774
Statistical and structural approaches to texture
Haralick, R. M. (1979) · Proceedings of the IEEE · doi:10.1109/proc.1979.11328 · Cited by 5,759
Strang, G., & Nguyen, T. Q. (1996) · Cited by 4,180
Multifrequency channel decompositions of images and wavelet models
Mallat, S. G. (1989) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/29.45554 · Cited by 1,955
Fractal-Based Description of Natural Scenes
Pentland, A. P. (1984) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1984.4767591 · Cited by 1,800
A Comparative Study of Texture Measures for Terrain Classification
Weszka, J. S., Dyer, C. R., & Rosenfeld, A. (1976) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1976.5408777 · Cited by 1,522
Markov Random Field Texture Models
Cross, G. R., & Jain, A. K. (1983) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1983.4767341 · Cited by 1,414
Texture analysis of medical images
Castellano, G., Bonilha, L., Li, L. M., & Cendes, F. (2004) · Clinical Radiology · doi:10.1016/j.crad.2004.07.008 · Cited by 1,026
Cited by
CT Texture Analysis: Definitions, Applications, Biologic Correlates, and Challenges
Lubner, M. G., Smith, A. D., Sandrasegaran, K., Sahani, D. V., & Pickhardt, P. J. (2017) · RadioGraphics · doi:10.1148/rg.2017170056 · Cited by 773
Intrinsic dependencies of CT radiomic features on voxel size and number of gray levels
Shafiq‐ul‐Hassan, M., Zhang, G. G., Latifi, K., Ullah, G., Hunt, D. C., Balagurunathan, Y., Abdalah, M. A., Schabath, M. B., Goldgof, D. G., Mackin, D., et al. (2017) · Medical Physics · doi:10.1002/mp.12123 · Cited by 585
Characterization of PET/CT images using texture analysis: the past, the present… any future?
Hatt, M., Tixier, F., Pierce, L., Kinahan, P. E., Le Rest, C. C., & Visvikis, D. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3427-0 · Cited by 475
Radiomics in Oncology: A Practical Guide
Shur, J. D., Doran, S. J., Kumar, S., ap Dafydd, D., Downey, K., O’Connor, J. P. B., Papanikolaou, N., Messiou, C., Koh, D.-M., & Orton, M. R. (2021) · RadioGraphics · doi:10.1148/rg.2021210037 · Cited by 378
Larue, R. T. H. M., Defraene, G., De Ruysscher, D., Lambin, P., & van Elmpt, W. (2017) · The British Journal of Radiology · doi:10.1259/bjr.20160665 · Cited by 363
CT texture analysis using the filtration-histogram method: what do the measurements mean?
Miles, K. A., Ganeshan, B., & Hayball, M. P. (2013) · Cancer Imaging · doi:10.1102/1470-7330.2013.9045 · Cited by 308
Self-citationLubner, M. G., Stabo, N., Lubner, S. J., del Rio, A. M., Song, C., Halberg, R. B., & Pickhardt, P. J. (2015) · Abdominal Imaging · doi:10.1007/s00261-015-0438-4 · Cited by 276
He, L., Huang, Y., Ma, Z., Liang, C., Liang, C., & Liu, Z. (2016) · Scientific Reports · doi:10.1038/srep34921 · Cited by 256
Limitations and Pitfalls of FDG-PET/CT in Infection and Inflammation
Pijl, J. P., Nienhuis, P. H., Kwee, T. C., Glaudemans, A. W. J. M., Slart, R. H. J. A., & Gormsen, L. C. (2021) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2021.06.008 · Cited by 229
Mapping spatial heterogeneity in the tumor microenvironment: a new era for digital pathology
Heindl, A., Nawaz, S., & Yuan, Y. (2015) · Laboratory Investigation · doi:10.1038/labinvest.2014.155 · Cited by 216
Radiomics and Artificial Intelligence for Biomarker and Prediction Model Development in Oncology
Forghani, R., Savadjiev, P., Chatterjee, A., Muthukrishnan, N., Reinhold, C., & Forghani, B. (2019) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2019.07.001 · Cited by 195
“For example, on computed tomography (CT), texture analysis can be used to analyze the distribution and relationship of pixel or voxel grey levels on an image, quantifying the coarseness and regularity that results from local spatial variations in image brightness [4,22].”
MethodPrediction of Pancreatic Neuroendocrine Tumor Grade Based on CT Features and Texture Analysis
Canellas, R., Burk, K. S., Parakh, A., & Sahani, D. V. (2018) · American Journal of Roentgenology · doi:10.2214/ajr.17.18417 · Cited by 169
Ho, L. M., Samei, E., Mazurowski, M. A., Zheng, Y., Allen, B. C., Nelson, R. C., & Marin, D. (2019) · American Journal of Roentgenology · doi:10.2214/ajr.18.20097 · Cited by 65
Distinguishing metastases from benign adrenal masses: what can CT texture analysis do?
Shi, B., Zhang, G.-M.-Y., Xu, M., Jin, Z.-Y., & Sun, H. (2019) · Acta Radiologica · doi:10.1177/0284185119830292 · Cited by 34
Saad, M., & Choi, T.-S. (2018) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2018.04.003 · Cited by 23
Metadata
- Authors
- Ganeshan, B., & Miles, K. A.
- Venue
- Cancer Imaging
- Publisher
- E-MED LTD
- Published
- 2013
- Volume
- 13
- Issue
- 1
- Pages
- 140-149
- ISSN
- 1470-7330 (ISSN-L)
- OpenAlex
- W2025811877
- Cited by
- 395
- References
- 63
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.