The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Optical Detection of Magnetic Resonance in Alkali Metal Vapor
Abstract
This paper discusses two types of rf magnetic resonance experiments involving optical pumping in alkali vapor which have recently been suggested by Dehmelt. These experiments are, respectively, observation of a change of intensity at resonance of the transmitted pumping light, and observation of high-frequency intensity modulation in a second light beam (the "cross beam") incident at an angle to the first. The method of pumping used here is reviewed, together with some of the special assumptions on which it is based. The function of the light in monitoring population differences is treated as a separate matter from the pumping function; it is shown that the observed changes in transmitted light intensity can be correlated in a simple way with other observables of a spin system, and this leads to a simple explanation of the high-frequency modulation effects. A system of spin-\textonehalf{} particles subject to optical pumping and monitoring is then treated phenomenologically. The resulting equations have the same form as Bloch's equations except that (1) the time constants must include effects of the incident light, and (2) there is an additional term due to the cross beam which, however, is shown to have no effect on the shape of the resonance.The apparatus is described, together with experimental conditions under which signals have been observed. Possible applications of the technique include magnetic-field measurements, and studies of atomic constants of alkali metal isotopes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bloch, F. (1946) · Physical Review · doi:10.1103/physrev.70.460 · Cited by 3,676
Description of States in Quantum Mechanics by Density Matrix and Operator Techniques
Fano, U. (1957) · Reviews of Modern Physics · doi:10.1103/revmodphys.29.74 · Cited by 1,975
The Dynamical Theory of Nuclear Induction
Wangsness, R. K., & Bloch, F. (1953) · Physical Review · doi:10.1103/physrev.89.728 · Cited by 828
Dynamical Theory of Nuclear Induction. II
Bloch, F. (1956) · Physical Review · doi:10.1103/physrev.102.104 · Cited by 443
Modulation of a Light Beam by Precessing Absorbing Atoms
Dehmelt, H. G. (1957) · Physical Review · doi:10.1103/physrev.105.1924 · Cited by 227
Slow Spin Relaxation of Optically Polarized Sodium Atoms
Dehmelt, H. G. (1957) · Physical Review · doi:10.1103/physrev.105.1487 · Cited by 206
Cited by
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
HAPPER, W. (1972) · Reviews of Modern Physics · doi:10.1103/revmodphys.44.169 · Cited by 1,710
Resonant nonlinear magneto-optical effects in atoms
Budker, D., Gawlik, W., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Weis, A. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.1153 · Cited by 809
Optically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400
Subpicotesla atomic magnetometry with a microfabricated vapour cell
Shah, V., Knappe, S., Schwindt, P. D. D., & Kitching, J. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.201 · Cited by 415
Metadata
- Authors
- Bell, W. E., & Bloom, A. L.
- Venue
- Physical Review
- Publisher
- American Physical Society (APS)
- Published
- 1957-09-15
- Volume
- 107
- Issue
- 6
- Pages
- 1559-1565
- ISSN
- 0031-899X (ISSN-L)
- OpenAlex
- W1976755501
- Cited by
- 268
- References
- 6
- FWCI
- 5.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.