Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 288

The DOI matches its Crossref record.

Electron Emission from Metals as a Function of Temperature

Dushman, Saul·1923·Physical Review

Abstract

Electron emission from metals as a function of temperature.---(1) General equation. The emission of electrons from a metal may be considered as thermodynamically equivalent to the evaporation of a monatomic gas, for which an equation is derived on the basis of the Nernst heat theorem. If it is assumed that the specific heat of free electrons in the metal is negligible while the specific heat of the evaporated electrons is the same as that of a monatomic gas, the equation assumes the simple form $I=A{T}^{2}{\ensuremath{\epsilon}}^{\frac{\ensuremath{-}{b}_{0}}{T}}$, where ${b}_{0}=\frac{{\ensuremath{\phi}}_{0}e}{k}$ ($e$ is electronic charge, $k$ is the Boltzmann constant, and ${\ensuremath{\phi}}_{0}=\frac{\ensuremath{\phi}\ensuremath{-}\frac{3}{2}\mathrm{kT}}{e}$, where $\ensuremath{\phi}$ is the Richardson work function). An equation of this form has been suggested before but not on the same theoretical grounds and a different value of $A$ has been obtained. Its chief advantage over the usual Richardson equation, $I={A}_{1}{T}^{\frac{1}{2}}{\ensuremath{\epsilon}}^{\frac{\ensuremath{-}b}{T}}$, where $b=\frac{\ensuremath{\phi}e}{k}$, is that $A$ is theoretically a universal constant. (2) The value of the universal emission constant $A$ is computed in two ways. Using the Sackur-Tetrode equation for the chemical constant ${i}_{0}$, $A$ comes out 60.2 amp./${\mathrm{cm}}^{2}$ ${\mathrm{deg}.}^{2}$, while the theory of rational units of Lewis, Gibson and Latimer gives 50.2 amp./${\mathrm{cm}}^{2}$ ${\mathrm{deg}.}^{2}$. Recent experimental results of Davisson and Germer, and of Schlichter as well as data obtained by the writer agree with the new equation as well or better than with the old, but the temperature scale is not sufficiently accurately known to distinguish experimentally between the two values of $A$. (3) The relation between A and the chemical constant ${i}_{0}$ (or ${C}_{0}$) is derived.Values of the work function in equivalent volts have been computed from the experimentally determined values of ${b}_{0}$, for tungsten (4.53), thorium (2.94), molybdenum (4.31), tantalum (4.40), and calcium (2.24) within \textonehalf{} to 1 per cent. The values for uranium (3.28), zirconium (3.28), yttrium (3.19) and cerium (3.07) are upper limits. In general, the values are lower the larger the atomic volumes. Experimental details will be given later.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrev.21.623

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Dushman, S.
Venue
Physical Review
Published
1923-06-01
Volume
21
Issue
6
Pages
623-636
ISSN
0031-899X (ISSN-L)
OpenAlex
W2075229461
Cited by
288
References
0
FWCI
23.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.