Number dependency in the compensated Penning trap
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Due to the increasing role that highly charged ions play in high-precision mass-ratio measurements within a compensated Penning trap, it is imperative that we investigate the dependency of the normal-mode frequencies on the total number of trapped charges. The experimental number dependency has been measured for four different ion species with various states of ionization. The absolute shift in both the observable cyclotron and magnetron frequencies is 0.018(3) Hz per equivalent electronic charge for a trap with characteristic dimension of 0.114 cm (in a 5-T field). The source of this systematic dependency has been traced to image charges induced on the surface of the trapping electrodes, whose electric field at the ion's position near trap center is approximately linear in the displacement of the trapped ions. A simple spherical model has been developed that is useful as a guide in minimizing this systematic effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Geonium theory: Physics of a single electron or ion in a Penning trap
Brown, L. S., & Gabrielse, G. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.233 · Cited by 1,367
Principles of the stored ion calorimeter
Wineland, D. J., & Dehmelt, H. G. (1975) · Journal of Applied Physics · doi:10.1063/1.321602 · Cited by 328
Gabrielse, G. (1983) · Physical Review A · doi:10.1103/physreva.27.2277 · Cited by 97
High mass resolution with a new variable anharmonicity Penning trap
Van Dyck, R. S., Wineland, D. J., Ekstrom, P. A., & Dehmelt, H. G. (1976) · Applied Physics Letters · doi:10.1063/1.88793 · Cited by 87
Cited by
High-accuracy mass spectrometry with stored ions
Blaum, K. (2006) · Physics Reports · doi:10.1016/j.physrep.2005.10.011 · Cited by 685
Häffner, H., Beier, T., Hermanspahn, N., Kluge, H.-J., Quint, W., Stahl, S., Verdú, J., & Werth, G. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.5308 · Cited by 285
Thousandfold improvement in the measured antiproton mass
Gabrielse, G., Fei, X., Orozco, L., Tjoelker, R., Haas, J., Kalinowsky, H., Trainor, T., & Kells, W. (1990) · Physical Review Letters · doi:10.1103/physrevlett.65.1317 · Cited by 275
g Factor of Hydrogenlike Si13+28
(2011) · Physical Review Letters · doi:10.1103/physrevlett.107.023002 · Cited by 176
Ultrastable superconducting magnet system for a penning trap mass spectrometer
Van Dyck, R. S., Farnham, D. L., Zafonte, S. L., & Schwinberg, P. B. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149649 · Cited by 63
Self-citation
Metadata
- Authors
- Van Dyck, R. S., Moore, F. L., Farnham, D. L., & Schwinberg, P. B.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 1989-12-01
- Volume
- 40
- Issue
- 11
- Pages
- 6308-6313
- ISSN
- 0556-2791 (ISSN-L)
- OpenAlex
- W2082200572
- Cited by
- 94
- References
- 4
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.