CoChat

Ultrastable superconducting magnet system for a penning trap mass spectrometer

Van Dyck, R. S., Farnham, D. L., Zafonte, S. L., Schwinberg, P. B. · 1999 · Review of Scientific Instruments

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

A custom-designed magnet/cryostat system is described which has demonstrated remarkably improved field stability over previous designs. To shield from external magnetic noise, a custom-fabricated flux-gate device remotely senses the changes in magnetic field and cancels them out at the site of the magnet/cryostat via a 1.7-m-diam Helmholtz coil. To provide further shielding, the basic superconducting solenoid includes a passive flux-stabilizing coil. To stabilize internal field shifts, the temperature of the materials in the immediate vicinity of the solenoid (which have a temperature-dependent susceptibility) is stabilized via the new cryostat geometry and by controlling the pressure of the evaporating liquid helium to a few parts per million. As a result, the total system now has a composite shielding factor of approximately 104 and an overall temporal stability on the order of 17(2) parts in 1012 per hour. This instrument, the heart of our new Penning trap mass spectrometer, has recently been used to determine a preliminary value of the proton’s atomic mass to an accuracy of 1.4 parts in 1010. With the new magnet/cryostat system, this spectrometer now has a potential resolution which exceeds 2 parts in 1011 with 100 hours of data using a single carbon 4+ ion.

Overview

Integrity signals

Registry

Crossref · 10.1063/1.1149649

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 14 references

Research works printed but not linked: 1

  1. 1990, Physica B, 165&166, 147

Cited by

See all 69

Metadata

Authors
Van Dyck, R. S., Farnham, D. L., Zafonte, S. L., & Schwinberg, P. B.
Affiliations
  • Department of Physics, Box 351560, University of Washington, Seattle, Washington 98195-1560
  • University of Washington (US)
Venue
Review of Scientific Instruments
Published
1999-03-01
Volume
70
Issue
3
Pages
1665-1671
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W2056891542
Cited by
63
References
14
Citations by year
2026: 1 · 2025: 6 · 2024: 2 · 2023: 2 · 2022: 1 · 2021: 2 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 3 · 2014: 1 · 2013: 4 · 2012: 2
FWCI
5.06
Type
journal article
Language
en
Open access
closed
Locations
Review of Scientific Instruments (publishedVersion)
Topics
  • Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle accelerators and beam dynamics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
Keywords
superconducting magnets, Penning trap mass spectrometer, magnetic field stability, cryostat design, Helmholtz coil, temperature stabilization, high-resolution mass spectrometry, carbon ions

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrastable superconducting magnet system for a penning trap mass spectrometer. https://app.cochat.ai/papers/10.1063/1.1149649
The paper
Van Dyck, R. S., Farnham, D. L., Zafonte, S. L., & Schwinberg, P. B. (1999). Ultrastable superconducting magnet system for a penning trap mass spectrometer. Review of Scientific Instruments. https://doi.org/10.1063/1.1149649

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.