High-efficiency single-photon detectors
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Using correlated photon pairs produced via spontaneous parametric down-conversion, we have measured the absolute single-photon detection efficiencies and time responses of four detectors: two solid-state photomultipliers (SSPM's) manufactured by Rockwell International Corp., and two custom-modified single-photon counting modules (SSPM's) manufactured by EG, Canada. The highest observed efficiencies were 70.9\ifmmode\pm\else\textpm\fi{}1.9% (with an SSPM, at a wavelength of 632 nm) and 76.4\ifmmode\pm\else\textpm\fi{}2.3% (with an SPCM, at 702 nm). We believe these to be the highest reported single-photon detection efficiencies in the visible spectrum; they are important for quantum cryptography and loophole-free tests of Bell's inequalities, as well as more prosaic applications such as photon correlation spectroscopy and velocimetry. We found that the time profile for coincidences between the SSPM and the SPCM consisted of a main peak with a 3.5-ns full width at half maximum (FWHM) preceded by a smaller peak by 11 ns. A similar time profile between two SPCM's displayed only one peak, with a 300-ps FWHM. Afterpulses were detected in the SPCM's at a level of less than ${10}^{\mathrm{\ensuremath{-}}4}$ of the counting rate, with an exponential decay time constant of 4.5 \ensuremath{\mu}s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the Einstein Podolsky Rosen paradox
Bell, J. S. (1964) · Physics Physique Fizika · doi:10.1103/physicsphysiquefizika.1.195 · Cited by 12,252
Quantum cryptography based on Bell’s theorem
Ekert, A. K. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.661 · Cited by 10,777
A single quantum cannot be cloned
Wootters, W. K., & Zurek, W. H. (1982) · Nature · doi:10.1038/299802a0 · Cited by 5,406
Bell’s Theorem, Quantum Theory and Conceptions of the Universe
(1989) · doi:10.1007/978-94-017-0849-4 · Cited by 1,632
Experimental consequences of objective local theories
Clauser, J. F., & Horne, M. A. (1974) · Physical Review D · doi:10.1103/physrevd.10.526 · Cited by 1,537
Eberhard, P. H. (1993) · Physical Review A · doi:10.1103/physreva.47.r747 · Cited by 582
Self-citationPractical quantum cryptography based on two-photon interferometry
Ekert, A. K., Rarity, J. G., Tapster, P. R., & Massimo Palma, G. (1992) · Physical Review Letters · doi:10.1103/physrevlett.69.1293 · Cited by 340
Cited by
Gisin, N., Ribordy, G., Tittel, W., & Zbinden, H. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.145 · Cited by 8,515
Measurement of the single-photon tunneling time
Steinberg, A. M., Kwiat, P. G., & Chiao, R. Y. (1993) · Physical Review Letters · doi:10.1103/physrevlett.71.708 · Cited by 830
Self-citationKwiat, P. G. (1997) · Journal of Modern Optics · doi:10.1080/09500349708231877 · Cited by 368
Self-citationKwiat, P. G., & Weinfurter, H. (1998) · Physical Review A · doi:10.1103/physreva.58.r2623 · Cited by 287
Self-citationMicrolaser: A laser with One Atom in an Optical Resonator
An, K., Childs, J. J., Dasari, R. R., & Feld, M. S. (1994) · Physical Review Letters · doi:10.1103/physrevlett.73.3375 · Cited by 283
Metadata
- Authors
- Kwiat, P. G., Steinberg, A. M., Chiao, R. Y., Eberhard, P. H., & Petroff, M. D.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 1993-08-01
- Volume
- 48
- Issue
- 2
- Pages
- R867-R870
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W2015344642
- Cited by
- 109
- References
- 7
- FWCI
- 10.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-efficiency single-photon detectors. https://app.cochat.ai/papers/10.1103/physreva.48.r867
- The paper
- Kwiat, P. G., Steinberg, A. M., Chiao, R. Y., Eberhard, P. H., & Petroff, M. D. (1993). High-efficiency single-photon detectors. Physical Review A. https://doi.org/10.1103/physreva.48.r867
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.