Atomic Deuterium Maser
The DOI matches its Crossref record.
Abstract
An atomic deuterium maser operating on hyperfine transitions was used to measure the ground-state hyperfine separation in deuterium. The result was ${\ensuremath{\nu}}_{0}(\mathrm{D})=327 384 352.5222(17)$ Hz where the hydrogen hyperfine frequency is assumed to be exactly 1420 405 751. 768 Hz. The construction of the device is discussed and a theory of the deuterium maser is presented with special attention given to frequency shifts occurring in the output frequency. In addition, a possible shift of the deuteron Larmor frequency because of the earth's gravitational field was also investigated and found to be ${10}^{\ensuremath{-}4}$ Hz.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Search for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560
Nobel Lecture: Superposition, entanglement, and raising Schrödinger’s cat
Wineland, D. J. (2013) · Reviews of Modern Physics · doi:10.1103/revmodphys.85.1103 · Cited by 503
Self-citationPrecision physics of simple atoms: QED tests, nuclear structure and fundamental constants
Karshenboim, S. G. (2005) · Physics Reports · doi:10.1016/j.physrep.2005.08.008 · Cited by 383
Constraints on Lorentz violation from clock-comparison experiments
Kostelecký, V. A., & Lane, C. D. (1999) · Physical Review D · doi:10.1103/physrevd.60.116010 · Cited by 378
NIST-F1: recent improvements and accuracy evaluations
Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/012 · Cited by 355
Hydrogen-Deuterium1S−2SIsotope Shift and the Structure of the Deuteron
Huber, A., Udem, T., Gross, B., Reichert, J., Kourogi, M., Pachucki, K., Weitz, M., & Hänsch, T. W. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.468 · Cited by 202
Limits for Spatial Anisotropy by Use of Nuclear-Spin-PolarizedBe+9Ions
Prestage, J. D., Bollinger, J. J., Itano, W. M., & Wineland, D. J. (1985) · Physical Review Letters · doi:10.1103/physrevlett.54.2387 · Cited by 200
Self-citationSearch for a coupling of the Earth’s gravitational field to nuclear spins in atomic mercury
Venema, B. J., Majumder, P. K., Lamoreaux, S. K., Heckel, B. R., & Fortson, E. N. (1992) · Physical Review Letters · doi:10.1103/physrevlett.68.135 · Cited by 164
Test of Cosmic Spatial Isotropy for Polarized Electrons Using a Rotatable Torsion Balance
Hou, L.-S., Ni, W.-T., & Li, Y.-C. M. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.201101 · Cited by 103
Metadata
- Authors
- Wineland, D. J., & Ramsey, N. F.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 1972-02-01
- Volume
- 5
- Issue
- 2
- Pages
- 821-837
- ISSN
- 0556-2791 (ISSN-L)
- OpenAlex
- W1987915577
- Cited by
- 90
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.