The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
NIST-F1: recent improvements and accuracy evaluations
Open accessAbstract
In the last several years we have made many improvements to NIST-F1 (a laser-cooled Cs fountain primary frequency standard at the National Institute of Standards and Technology (NIST) in Boulder, Colorado) resulting in a reduction by over a factor of 2 in the uncertainty of the realization of the SI second. The two most recent accuracy evaluations of NIST-F1 had combined standard fractional uncertainties of 0.61 × 10 −15 (June 2004) and 0.53 × 10 −15 (January 2005), which were submitted to the Bureau International des Poids et Mesures with total fractional uncertainties (including time-transfer contributions) of, respectively, 0.88 × 10 −15 and 0.97 × 10 −15 . Here we discuss the improvements and evaluation methods and present an updated uncertainty budget.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Atomic clocks with the stability level of 10 -16 have been created [19][20][21].”
From Determination of the geopotential and orthometric height based on frequency shift equation (2011) · cites this paper as [19]
Citations
Cites
Guidelines for evaluating and expressing the uncertainty of NIST measurement results
Taylor, B. N., & Kuyatt, C. E. (2018) · doi:10.6028/nist.tn.1297-1993 · Cited by 2,582
The Quantum Physics of Atomic Frequency Standards: Recent Developments
Vanier, J., & Tomescu, C. (2015) · CRC Press eBooks · doi:10.1201/b18738 · Cited by 553
Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results, | NIST
Taylor, B. N., & Kuyatt, C. E. (1993) · Cited by 514
Accuracy evaluation of NIST-F1
Jefferts, S. R., Shirley, J., Parker, T. E., Heavner, T. P., Meekhof, D. M., Nelson, C., Levi, F., Costanzo, G., Marchi, A. D., Drullinger, R., et al. (2002) · Metrologia · doi:10.1088/0026-1394/39/4/1 · Cited by 402
Self-citationParker, T. E., Jefferts, S. R., Heavner, T. P., & Donley, E. A. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/013 · Cited by 220
Self-citationThe Quantum Physics of Atomic Frequency Standards
Vanier, J., & Audoin, C. (1989) · Taylor & Francis eBooks · doi:10.1201/9781420050851 · Cited by 180
Arditi, M., & Carver, T. R. (1961) · Physical Review · doi:10.1103/physrev.124.800 · Cited by 174
Measurement and Cancellation of the Cold Collision Frequency Shift in an 87Rb Fountain Clock
Fertig, C., & Gibble, K. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.1622 · Cited by 153
Measurement of the Stark shift of the Cs hyperfine splitting in an atomic fountain
Simon, E., Laurent, P., & Clairon, A. (1998) · Physical Review A · doi:10.1103/physreva.57.436 · Cited by 141
Controlling the Cold Collision Shift in High Precision Atomic Interferometry
dos Santos, F. P., Marion, H., Bize, S., Sortais, Y. R. P., Clairon, A., & Salomon, C. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.233004 · Cited by 110
Research works printed but not linked: 7
- Howe D A Peppler T K, 2003, Proc. 2003 Joint Meeting IEEE Int. Freq. Control Symp. and EFTF Conf., 233
- Nava J H Walls F L Shirley J H Lee W D Armburo M M, 1996, Proc. 1996 IEEE Int. Freq. Control Symp., 973
- Parker T E, 2001, Proc. 2001 IEEE Int. Freq. Control Symp., 57
- 10.1103/physrevlett86.3743 · doi:10.1103/physrevlett86.3743
- Jefferts S R, 2005, IEEE Trans. Ultrason. Ferr.
- Jefferts S R Shirley J H Ashby N Heavner T P Donley E A Levi F Burt E A Dick G J, 2005, Proc. 19th Eur. Time and Frequency Forum
- Lee W D Shirley J H Walls F L Drullinger R E, 1995, Proc. 1995 IEEE Int. Freq. Control Symp., 113
Cited by
Nobel Lecture: Defining and measuring optical frequencies
Hall, J. L. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1279 · Cited by 614
Sr Lattice Clock at 1 × 10 –16 Fractional Uncertainty by Remote Optical Evaluation with a Ca Clock
Ludlow, A. D., Zelevinsky, T., Campbell, G. K., Blatt, S., Boyd, M. M., de Miranda, M. H. G., Martin, M. J., Thomsen, J. W., Foreman, S. M., Ye, J., et al. (2008) · Science · doi:10.1126/science.1153341 · Cited by 554
Quantum State Engineering and Precision Metrology Using State-Insensitive Light Traps
Ye, J., Kimble, H. J., & Katori, H. (2008) · Science · doi:10.1126/science.1148259 · Cited by 419
Prospects for a Millihertz-Linewidth Laser
Meiser, D., Ye, J., Carlson, D. R., & Holland, M. J. (2009) · Physical Review Letters · doi:10.1103/physrevlett.102.163601 · Cited by 378
Single-Atom Optical Clock with High Accuracy
Oskay, W. H., Diddams, S. A., Donley, E. A., Fortier, T. M., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Delaney, M. J., Kim, K., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.020801 · Cited by 297
Self-citation
Metadata
- Authors
- Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E.
- Affiliations
- National Institute of Standards and Technology (US)
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2005-09-13
- Volume
- 42
- Issue
- 5
- Pages
- 411-422
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2132308827
- Cited by
- 355
- References
- 22
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 1 · 2023: 1 · 2022: 9 · 2021: 19 · 2020: 16 · 2019: 18 · 2018: 15 · 2017: 14 · 2016: 16 · 2015: 15 · 2014: 23 · 2013: 21 · 2012: 3
- FWCI
- 18.17
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Metrologia (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Keywords
- primary frequency standard, fractional frequency uncertainty, uncertainty budget, time transfer, accuracy assessment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: NIST-F1: recent improvements and accuracy evaluations. https://app.cochat.ai/papers/10.1088/0026-1394/42/5/012
- The paper
- Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005). NIST-F1: recent improvements and accuracy evaluations. Metrologia. https://doi.org/10.1088/0026-1394/42/5/012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.