Cited by 516Quantum Information and CryptographyPhotorefractive and Nonlinear OpticsQuantum optics and atomic interactions

Spectral information and distinguishability in type-II down-conversion with a broadband pump

Grice, W. P., Walmsley, I. A.·1997·Physical Review A

Abstract

A model is presented to describe spontaneous type-II parametric down-conversion pumped by a broadband source. This process differs from the familiar cw-pumped down-conversion in that a broader range of pump energies is available for down-conversion. The properties of the nonlinear crystal determine how these energies are distributed into the down-converted photons. Because the two photons are polarized along different crystal axes, they have different spectral characteristics and are no longer exactly anticorrelated. As the pump bandwidth is increased, this effect becomes more pronounced. A fourth-order interference experiment is proposed, illustrating some of the features of broadband pumped down-conversion.

Integrity signals

Registry

Crossref · 10.1103/physreva.56.1627

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Methods used to increase quantum interference visibility include: (i) a thin nonlinear crystal, (ii) narrow-band spectral filters in front of detectors, or (iii) an interferometric technique without spectral and amplitude post-selection.

    “The following methods are used to increase the quantum interference visibility: (i) a thin nonlinear crystal (Sergienko et al., 1999), (ii) narrow-band spectral filters in front of detectors, as shown above (Grice and Walmsley, 1997;Grice et al., 1998;Di Giuseppe et al., 1997), or (iii) an interferometric technique (Branning et al., 1999(Branning et al., , 2000) ) without spectral and amplitude”

    From Multiphoton entanglement and interferometry (2012) · cites this paper as Grice and Walmsley, 1997

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Grice, W. P., & Walmsley, I. A.
Affiliations
University of Rochester (US)
Venue
Physical Review A
Published
1997-08-01
Volume
56
Issue
2
Pages
1627-1634
ISSN
  • 0556-2791 (ISSN-L)
  • 1050-2947
  • 1094-1622
OpenAlex
W2000991915
Cited by
516
References
3
Citations by year
2026: 16 · 2025: 19 · 2024: 16 · 2023: 18 · 2022: 19 · 2021: 23 · 2020: 30 · 2019: 26 · 2018: 20 · 2017: 19 · 2016: 32 · 2015: 19 · 2014: 19 · 2013: 20 · 2012: 21
FWCI
6.62
Type
journal article
Language
en
Open access
closed
Locations
Physical Review A (publishedVersion)
Funders
National Science Foundation
Topics
  • Physical Sciences › Computer Science › Artificial Intelligence › Quantum Information and Cryptography
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Photorefractive and Nonlinear Optics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum optics and atomic interactions
Keywords
spontaneous parametric down-conversion, polarization-entangled photon pairs, pump bandwidth, nonlinear optical crystals, fourth-order interference, quantum optics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review