CoChat

Measurement of the Stark shift of the Cs hyperfine splitting in an atomic fountain

Simon, E., Laurent, P., Clairon, A. · 1998 · Physical Review A
Cited by 131

The DOI matches its Crossref record.

Abstract

We have used an atomic fountain frequency standard to perform a new measurement of the frequency shift induced by a static electric field $E$ on the clock transition of the cesium $6{}^{2}{S}_{1/2}$ hyperfine splitting. The result in units of ${\mathrm{H}\mathrm{z}/(\mathrm{V}/\mathrm{m})}^{2}$ is $\ensuremath{\delta}{\ensuremath{\nu}}_{0}=\ensuremath{-}2.271(4)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}10}{E}^{2}.$ The accuracy of this measurement represents a tenfold improvement over previous values. This result is of importance for testing ab initio theoretical calculations of the cesium atomic structure as well as semiempirical models used in parity violation experiments. It will also allow a better evaluation of the frequency shift induced by the blackbody radiation in cesium frequency standards.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physreva.57.436

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 131

Metadata

Authors
Simon, E., Laurent, P., & Clairon, A.
Venue
Physical Review A
Published
1998-01-01
Volume
57
Issue
1
Pages
436-439
ISSN
  • 0556-2791 (ISSN-L)
  • 1050-2947
  • 1094-1622
OpenAlex
W1977399298
Cited by
131
References
0
FWCI
4.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of the Stark shift of the Cs hyperfine splitting in an atomic fountain. https://app.cochat.ai/papers/10.1103/physreva.57.436
The paper
Simon, E., Laurent, P., & Clairon, A. (1998). Measurement of the Stark shift of the Cs hyperfine splitting in an atomic fountain. Physical Review A. https://doi.org/10.1103/physreva.57.436

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.