The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Quantum Projection Noise in an Atomic Fountain: A High Stability Cesium Frequency Standard
Abstract
We describe the operation of a laser cooled cesium fountain clock in the quantum limited regime. An ultrastable cryogenic sapphire oscillator is used to measure the short-term frequency stability of the fountain as a function of the number of detected atoms ${N}_{\mathrm{at}}$. For ${N}_{\mathrm{at}}$ varying from $4\ifmmode\times\else\texttimes\fi{}{10}^{4}$ to $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ the Allan standard deviation of the frequency fluctuations is in excellent agreement with the ${N}_{\mathrm{at}}^{\ensuremath{-}1/2}$ law of atomic projection noise. With $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ atoms, the relative frequency stability is $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$, where \ensuremath{\tau} is the integration time in seconds. This is the best short-term stability ever reported for primary frequency standards, a factor of 5 improvement over previous results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Santarelli, G., Audoin, C., Makdissi, A., Laurent, P., Dick, G. J., & Clairon, A. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.710548 · Cited by 314
Self-citation
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Atom-chip-based generation of entanglement for quantum metrology
Riedel, M. F., Böhi, P., Li, Y., Hänsch, T. W., Sinatra, A., & Treutlein, P. (2010) · Nature · doi:10.1038/nature08988 · Cited by 874
An Optical Clock Based on a Single Trapped 199 Hg + Ion
Diddams, S. A., Udem, T., Bergquist, J. C., Curtis, E. A., Drullinger, R. E., Hollberg, L., Itano, W. M., Lee, W. D., Oates, C. W., Vogel, K. R., et al. (2001) · Science · doi:10.1126/science.1061171 · Cited by 720
Niering, M., Holzwarth, R., Reichert, J., Pokasov, P., Udem, T., Weitz, M., Hänsch, T. W., Lemonde, P., Santarelli, G., Abgrall, M., et al. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5496 · Cited by 560
Self-citationMeasuring the frequency of light with mode-locked lasers
Reichert, J., Holzwarth, R., Udem, T., & Hänsch, T. W. (1999) · Optics Communications · doi:10.1016/s0030-4018(99)00491-5 · Cited by 473
Metadata
- Authors
- Santarelli, G., Laurent, P., Lemonde, P., Clairon, A., Mann, A. G., Chang, S., Luiten, A. N., & Salomon, C.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1999-06-07
- Volume
- 82
- Issue
- 23
- Pages
- 4619-4622
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2057478419
- Cited by
- 569
- References
- 2
- FWCI
- 14.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantum Projection Noise in an Atomic Fountain: A High Stability Cesium Frequency Standard. https://app.cochat.ai/papers/10.1103/physrevlett.82.4619
- The paper
- Santarelli, G., Laurent, P., Lemonde, P., Clairon, A., Mann, A. G., Chang, S., Luiten, A. N., & Salomon, C. (1999). Quantum Projection Noise in an Atomic Fountain: A High Stability Cesium Frequency Standard. Physical Review Letters. https://doi.org/10.1103/physrevlett.82.4619
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.