High-resolution spectroscopy of the1S−2Stransition in atomic hydrogen
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The sharp hydrogen $1S\ensuremath{-}2S$ two-photon transition is a promising candidate for the realization of a frequency standard based on an atomic transition in the optical region. In recent work we have used this transition to precisely determine the Rydberg constant, the $1S$ Lamb shift and the hydrogen-deuterium isotope shift. In this paper we focus on substantially improved spectroscopic methods leading to a much higher spectral resolution of the $1S\ensuremath{-}2S$ transition in hydrogen and deuterium. We have successfully applied a time-delayed measurement scheme, which allowed us to reduce the linewidth to 1 kHz at 243 nm corresponding to a spectral resolution of $\ensuremath{\Delta}\ensuremath{\nu}/\ensuremath{\nu}=8\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}.$ A theoretical line-shape model based on a solution of the Master equation allows us to determine the unperturbed hydrogen $1S\ensuremath{-}2S$ two-photon transition frequency from our spectra to a level of $1.5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}.$
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Experiments with separated oscillatory fields and hydrogen masers
Ramsey, N. F. (1990) · Reviews of Modern Physics · doi:10.1103/revmodphys.62.541 · Cited by 238
Cited by
Niering, M., Holzwarth, R., Reichert, J., Pokasov, P., Udem, T., Weitz, M., Hänsch, T. W., Lemonde, P., Santarelli, G., Abgrall, M., et al. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5496 · Cited by 560
Self-citationMeasuring the frequency of light with mode-locked lasers
Reichert, J., Holzwarth, R., Udem, T., & Hänsch, T. W. (1999) · Optics Communications · doi:10.1016/s0030-4018(99)00491-5 · Cited by 473
Self-citationNew Limits on the Drift of Fundamental Constants from Laboratory Measurements
Fischer, M., Kolachevsky, N., Zimmermann, M., Holzwarth, R., Udem, T., Hänsch, T. W., Abgrall, M., Grünert, J., Maksimovic, I., Bize, S., et al. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.230802 · Cited by 431
Self-citationThe CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Base units of the SI, fundamental constants and modern quantum physics
Bordé, C. J. (2005) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2005.1635 · Cited by 124
“10K12, thanks to the work of the groups of F. Biraben in Paris and T. Haensch in Garching; Huber et al. 1999; de Beauvoir et al. 2000).”
Background
Metadata
- Authors
- Huber, A., Gross, B., Weitz, M., & Hänsch, T. W.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 1999-03-01
- Volume
- 59
- Issue
- 3
- Pages
- 1844-1851
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W294263317
- Cited by
- 68
- References
- 1
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.