We report on an absolute frequency measurement of the hydrogen 1S-2S two-photon transition in a cold atomic beam with an accuracy of 1.8 parts in 10(14). Our experimental result of 2 466 061 413 187 103(46) Hz has been obtained by phase coherent comparison of the hydrogen transition frequency with an atomic cesium fountain clock. Both frequencies are linked with a comb of laser frequencies emitted by a mode locked laser.

Overview

Integrity signals

Registry

Crossref · 10.1103/physrevlett.84.5496

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Metadata

Authors
Niering, M., Holzwarth, R., Reichert, J., Pokasov, P., Udem, T., Weitz, M., Hänsch, T. W., Lemonde, P., Santarelli, G., Abgrall, M., Laurent, P., Salomon, C., & Clairon, A.
Affiliations
  • Max Planck Institute of Quantum Optics (DE)
  • Observatoire de Paris (FR)
  • Laboratoire Kastler Brossel (FR)
Venue
Physical Review Letters
Published
2000-06-12
Volume
84
Issue
24
Pages
5496-5499
ISSN
  • 0031-9007 (ISSN-L)
  • 1079-7114
OpenAlex
W2048929628
Cited by
560
References
24
Citations by year
2026: 2 · 2025: 13 · 2024: 4 · 2023: 6 · 2022: 8 · 2021: 4 · 2020: 6 · 2019: 13 · 2018: 18 · 2017: 14 · 2016: 13 · 2015: 17 · 2014: 10 · 2013: 16 · 2012: 19
FWCI
27.42
Type
journal article
Language
en
Open access
closed
Locations
  • Physical Review Letters (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
  • Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
Keywords
absolute frequency measurement, cesium fountain clock, cold atomic beam

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review