Quantum-limited metrology and Bose-Einstein condensates
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
We discuss a quantum-metrology protocol designed to estimate a physical parameter in a Bose-Einstein condensate of $N$ atoms, and we show that the measurement uncertainty can decrease faster than $1/N$. The $1/N$ scaling is usually thought to be the best possible in any measurement scheme. From the perspective of quantum information theory, we outline the main idea that leads to a measurement uncertainty that scales better than $1/N$. We examine in detail some potential problems and challenges that arise in implementing such a measurement protocol using a Bose-Einstein condensate. We discuss how some of these issues can be dealt with by using lower-dimensional condensates trapped in nonharmonic potentials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical distance and the geometry of quantum states
Braunstein, S. L., & Caves, C. M. (1994) · Physical Review Letters · doi:10.1103/physrevlett.72.3439 · Cited by 3,176
Self-citationProbabilistic and Statistical Aspects of Quantum Theory
Holevo, A. (2011) · doi:10.1007/978-88-7642-378-9 · Cited by 2,582
Giovannetti, V., Lloyd, S., & Maccone, L. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.010401 · Cited by 2,440
Optimal frequency measurements with maximally correlated states
Bollinger, J. J., Itano, W. M., Wineland, D. J., & Heinzen, D. J. (1996) · Physical Review A · doi:10.1103/physreva.54.r4649 · Cited by 1,167
Improvement of Frequency Standards with Quantum Entanglement
Huelga, S. F., Macchiavello, C., Pellizzari, T., Ekert, A. K., Plenio, M. B., & Cirac, J. I. (1997) · Physical Review Letters · doi:10.1103/physrevlett.79.3865 · Cited by 999
Generalized uncertainty relations: Theory, examples, and Lorentz invariance
Braunstein, S. L., Caves, C. M., & Milburn, G. J. (1996) · Annals of Physics · doi:10.1006/aphy.1996.0040 · Cited by 732
Self-citationGeneralized Limits for Single-Parameter Quantum Estimation
Boixo, S., Flammia, S. T., Caves, C. M., & Geremia, J. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.090401 · Cited by 403
Self-citation
Cited by
Quantum metrology with nonclassical states of atomic ensembles
Pezzè, L., Smerzi, A., Oberthaler, M. K., Schmied, R., & Treutlein, P. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.035005 · Cited by 1,682
Probing Planck-scale physics with quantum optics
Pikovski, I., Vanner, M. R., Aspelmeyer, M., Kim, M. S., & Brukner, Č. (2012) · Nature Physics · doi:10.1038/nphys2262 · Cited by 594
Quantum-enhanced measurements without entanglement
Braun, D., Adesso, G., Benatti, F., Floreanini, R., Marzolino, U., Mitchell, M. W., & Pirandola, S. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.035006 · Cited by 434
Fisher information under decoherence in Bloch representation
Zhong, W., Sun, Z., Ma, J., Wang, X., & Nori, F. (2013) · Physical Review A · doi:10.1103/physreva.87.022337 · Cited by 321
Interaction-based quantum metrology showing scaling beyond the Heisenberg limit
Napolitano, M., Koschorreck, M., Dubost, B., Behbood, N., Sewell, R. J., & Mitchell, M. W. (2011) · Nature · doi:10.1038/nature09778 · Cited by 245
Metadata
- Authors
- Boixo, S., Datta, A., Davis, M. J., Shaji, A., Tacla, A. B., & Caves, C. M.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2009-09-04
- Volume
- 80
- Issue
- 3
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W2054454767
- Cited by
- 72
- References
- 7
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantum-limited metrology and Bose-Einstein condensates. https://app.cochat.ai/papers/10.1103/physreva.80.032103
- The paper
- Boixo, S., Datta, A., Davis, M. J., Shaji, A., Tacla, A. B., & Caves, C. M. (2009). Quantum-limited metrology and Bose-Einstein condensates. Physical Review A. https://doi.org/10.1103/physreva.80.032103
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.