Heralded-qubit amplifiers for practical device-independent quantum key distribution
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Device-independent quantum key distribution does not need a precise quantum mechanical model of employed devices to guarantee security. Despite its beauty, it is still a very challenging experimental task. We compare a recent proposal by Gisin et al. [Phys. Rev. Lett. 105, 070501 (2010)] to close the detection loophole problem with that of a simpler quantum relay based on entanglement swapping with linear optics. Our full-mode analysis for both schemes confirms that, in contrast to recent beliefs, the second scheme can indeed provide a positive key rate which is even considerably higher than that of the first alternative. The resulting key rates and required detection efficiencies of approximately 95% for both schemes, however, strongly depend on the underlying security proof.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Proposed Experiment to Test Local Hidden-Variable Theories
Clauser, J. F., Horne, M. A., Shimony, A., & Holt, R. A. (1969) · Physical Review Letters · doi:10.1103/physrevlett.23.880 · Cited by 7,573
Counting near-infrared single-photons with 95% efficiency
Lita, A. E., Miller, A. J., & Nam, S. W. (2008) · Optics Express · doi:10.1364/oe.16.003032 · Cited by 734
From Bell’s Theorem to Secure Quantum Key Distribution
Acín, A., Gisin, N., & Masanes, L. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.120405 · Cited by 709
Hidden-Variable Example Based upon Data Rejection
Pearle, P. M. (1970) · Physical Review D · doi:10.1103/physrevd.2.1418 · Cited by 619
Cited by
Brunner, N., Cavalcanti, D., Pironio, S., Scarani, V., & Wehner, S. (2014) · Reviews of Modern Physics · doi:10.1103/revmodphys.86.419 · Cited by 2,688
Measurement-Device-Independent Quantum Key Distribution
Lo, H.-K., Curty, M., & Qi, B. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.130503 · Cited by 2,239
Self-citationSecure quantum key distribution with realistic devices
Xu, F., Ma, X., Zhang, Q., Lo, H.-K., & Pan, J.-W. (2020) · Reviews of Modern Physics · doi:10.1103/revmodphys.92.025002 · Cited by 1,543
Secure quantum key distribution
Lo, H.-K., Curty, M., & Tamaki, K. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.149 · Cited by 1,296
Self-citationBranciard, C., Cavalcanti, E. G., Walborn, S. P., Scarani, V., & Wiseman, H. M. (2012) · Physical Review A · doi:10.1103/physreva.85.010301 · Cited by 762
Metadata
- Authors
- Curty, M., & Moroder, T.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2011-07-27
- Volume
- 84
- Issue
- 1
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W2027289416
- Cited by
- 125
- References
- 4
- FWCI
- 11.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heralded-qubit amplifiers for practical device-independent quantum key distribution. https://app.cochat.ai/papers/10.1103/physreva.84.010304
- The paper
- Curty, M., & Moroder, T. (2011). Heralded-qubit amplifiers for practical device-independent quantum key distribution. Physical Review A. https://doi.org/10.1103/physreva.84.010304
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.