Measurement of ion motional heating rates over a range of trap frequencies and temperatures
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We present measurements of the motional heating rate of a trapped ion at different trap frequencies and temperatures between $\ensuremath{\sim}0.6$ and 1.5 MHz and $\ensuremath{\sim}4$ and 295 K. Additionally, we examine the possible effect of adsorbed surface contaminants with boiling points below $\ensuremath{\sim}105{\phantom{\rule{0.16em}{0ex}}}^{\ensuremath{\circ}}\mathrm{C}$ by measuring the ion heating rate before and after locally baking our ion trap chip under ultrahigh vacuum conditions. We compare the heating rates presented here to those calculated from available electric-field noise models. We can tightly constrain a subset of these models based on their expected frequency and temperature scaling interdependence. Discrepancies between the measured results and predicted values point to the need for refinement of theoretical noise models in order to more fully understand the mechanisms behind motional trapped-ion heating.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Resolved-Sideband Raman Cooling of a Bound Atom to the 3D Zero-Point Energy
Monroe, C., Meekhof, D. M., King, B. E., Jefferts, S. R., Itano, W. M., Wineland, D. J., & Gould, P. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.4011 · Cited by 731
Ion-trap measurements of electric-field noise near surfaces
Brownnutt, M., Kumph, M., Rabl, P., & Blatt, R. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.1419 · Cited by 413
Hite, D. A., Colombe, Y., Wilson, A. C., Brown, K. R., Warring, U., Jördens, R., Jost, J. D., McKay, K. S., Pappas, D. P., Leibfried, D., et al. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.103001 · Cited by 176
Randomized Benchmarking of Multiqubit Gates
Gaebler, J. P., Meier, A. M., Tan, T. R., Bowler, R., Lin, Y., Hanneke, D., Jost, J. D., Home, J. P., Knill, E., Leibfried, D., et al. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.260503 · Cited by 127
Cited by
Trapped-ion quantum computing: Progress and challenges
Bruzewicz, C. D., Chiaverini, J., McConnell, R., & Sage, J. M. (2019) · Applied Physics Reviews · doi:10.1063/1.5088164 · Cited by 1,483
Self-citationMaterials challenges and opportunities for quantum computing hardware
de Leon, N. P., Itoh, K. M., Kim, D., Mehta, K. K., Northup, T. E., Paik, H., Palmer, B. S., Samarth, N., Sangtawesin, S., & Steuerman, D. W. (2021) · Science · doi:10.1126/science.abb2823 · Cited by 710
Ion-trap measurements of electric-field noise near surfaces
Brownnutt, M., Kumph, M., Rabl, P., & Blatt, R. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.1419 · Cited by 413
Integrated multi-wavelength control of an ion qubit
Niffenegger, R. J., Stuart, J., Sorace-Agaskar, C., Kharas, D., Bramhavar, S., Bruzewicz, C. D., Loh, W., Maxson, R. T., McConnell, R., Reens, D., et al. (2020) · Nature · doi:10.1038/s41586-020-2811-x · Cited by 330
Self-citationScalable loading of a two-dimensional trapped-ion array
Bruzewicz, C. D., McConnell, R., Chiaverini, J., & Sage, J. M. (2016) · Nature Communications · doi:10.1038/ncomms13005 · Cited by 50
Self-citation
Metadata
- Authors
- Bruzewicz, C. D., Sage, J. M., & Chiaverini, J.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2015-04-13
- Volume
- 91
- Issue
- 4
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W2113980113
- Cited by
- 55
- References
- 4
- FWCI
- 6.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of ion motional heating rates over a range of trap frequencies and temperatures. https://app.cochat.ai/papers/10.1103/physreva.91.041402
- The paper
- Bruzewicz, C. D., Sage, J. M., & Chiaverini, J. (2015). Measurement of ion motional heating rates over a range of trap frequencies and temperatures. Physical Review A. https://doi.org/10.1103/physreva.91.041402
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.