Limits to the symmetry of a Mach-Zehnder-type atom interferometer
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Owing to the use of a symmetrization $\ensuremath{\pi}$ pulse at the middle of their laser sequences, Mach-Zehnder-type atom interferometers are insensitive to clocks shifts and Doppler shifts, if constant, but to changes in these quantities, which makes them accurate and sensitive inertial-force sensors. However, variations of the Raman laser coupling between laser pulses restore a parasitic sensitivity to the Doppler shift. This effect, which sets a limit to the symmetry of the interferometer, is quantitatively evaluated here as a function of the experimental parameters, in the case of an atom gravimeter experiment, and compared to expectations. We show in particular that velocity-distribution asymmetries lead to parasitic phase shifts that can compromise the accuracy and long-term stability of the gravity measurement in the low ${10}^{\ensuremath{-}9}g$ range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ladd, T. D., Jelezko, F., Laflamme, R., Nakamura, Y., Monroe, C., & O’Brien, J. L. (2010) · Nature · doi:10.1038/nature08812 · Cited by 3,592
Wynands, R., & Weyers, S. (2005) · Metrologia · doi:10.1088/0026-1394/42/3/s08 · Cited by 374
Cited by
Determination of the fine-structure constant with an accuracy of 81 parts per trillion
Morel, L., Yao, Z., Cladé, P., & Guellati-Khélifa, S. (2020) · Nature · doi:10.1038/s41586-020-2964-7 · Cited by 590
Gué, J., Hees, A., & Wolf, P. (2024) · Physical Review D · doi:10.1103/physrevd.110.035005 · Cited by 10
Metadata
- Authors
- Gillot, P., Cheng, B., Merlet, S., & Pereira Dos Santos, F.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2016-01-12
- Volume
- 93
- Issue
- 1
- ISSN
- 0556-2791 (ISSN-L)
- 2469-9926
- 2469-9934
- OpenAlex
- W2564801320
- Cited by
- 38
- References
- 2
- FWCI
- 1.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.