The DOI matches its Crossref record; 46 of the 48 references it cites were found in a registry or an index.
Determination of the fine-structure constant with an accuracy of 81 parts per trillion
Open accessAbstract
The standard model of particle physics is remarkably successful because it is consistent with (almost) all experimental results. However, it fails to explain dark matter, dark energy and the imbalance between matter and antimatter in the Universe. Because discrepancies between standard-model predictions and experimental observations may provide evidence of new physics, an accurate evaluation of these predictions requires highly precise values of the fundamental physical constants. Among them, the fine-structure constant α is of particular importance because it sets the strength of the electromagnetic interaction between light and charged elementary particles, such as the electron and the muon. Here we use matter-wave interferometry to measure the recoil velocity of a rubidium atom that absorbs a photon, and determine the fine-structure constant α-1 = 137.035999206(11) with a relative accuracy of 81 parts per trillion. The accuracy of eleven digits in α leads to an electron g factor 1,2-the most precise prediction of the standard model-that has a greatly reduced uncertainty. Our value of the fine-structure constant differs by more than 5 standard deviations from the best available result from caesium recoil measurements 3. Our result modifies the constraints on possible candidate dark-matter particles proposed to explain the anomalous decays of excited states of 8 Be nuclei 4 and paves the way for testing the discrepancy observed in the magnetic moment anomaly of the muon 5 in the electron sector 6.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It is to be noted that these two latter values differ by 5.5r!”
From Fundamental constants: from measurement to the universe, a window on gravitation and cosmology (2025) · cites this paper as Morel et al. 2020
Citations
Cites
Final report of the E821 muon anomalous magnetic moment measurement at BNL
Bennett, G. W., Bousquet, B., Brown, H. N., Bunce, G., Carey, R. M., Cushman, P., Danby, G. T., Debevec, P. T., Deile, M., Deng, H., et al. (2006) · Physical Review D · doi:10.1103/physrevd.73.072003 · Cited by 2,451
CODATA recommended values of the fundamental physical constants: 2010
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2012) · Reviews of Modern Physics · doi:10.1103/revmodphys.84.1527 · Cited by 2,441
New measurement of the electron magnetic moment and the fine structure constant
Hanneke, D., Fogwell, S., & Gabrielse, G. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.120801 · Cited by 1,138
CODATA recommended values of the fundamental physical constants: 2014
Mohr, P. J., Newell, D. B., & Taylor, B. N. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.035009 · Cited by 920
Measurement of the fine-structure constant as a test of the Standard Model
Parker, R. H., Yu, C., Zhong, W., Estey, B., & Müller, H. (2018) · Science · doi:10.1126/science.aap7706 · Cited by 917
New high-precision comparison of electron and positron g factors
Van Dyck, R. S., Schwinberg, P. B., & Dehmelt, H. G. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.26 · Cited by 659
Anomalous magnetic moment and limits on fermion substructure
Brodsky, S. J., & Drell, S. D. (1980) · Physical Review D · doi:10.1103/physrevd.22.2236 · Cited by 597
New Determination of the Fine Structure Constant and Test of the Quantum Electrodynamics
Bouchendira, R., Cladé, P., Guellati-Khélifa, S., Nez, F., & Biraben, F. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.080801 · Cited by 568
Self-citationSearch for a Dark Photon ine+e−Collisions at BaBar
Lees, J. P., Poireau, V., Tisserand, V., Grauges, E., Palano, A., Eigen, G., Stugu, B., Brown, D. N., Feng, M., Kerth, L. T., et al. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.201801 · Cited by 517
Search for short-lived axions in an electron-beam-dump experiment
Riordan, E. M., Krasny, M. W., Lang, K., de Barbaro, P., Bodek, A., Dasu, S., Varelas, N., Wang, X., Arnold, R., Benton, D., et al. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.755 · Cited by 486
Cited by
The AME 2020 atomic mass evaluation (I). Evaluation of input data, and adjustment procedures*
Huang, W. J., Wang, M., Kondev, F. G., Audi, G., & Naimi, S. (2021) · Chinese Physics C · doi:10.1088/1674-1137/abddb0 · Cited by 436
Measurement of the Electron Magnetic Moment
Fan, X., Myers, T. G., Sukra, B. A. D., & Gabrielse, G. (2023) · Physical Review Letters · doi:10.1103/physrevlett.130.071801 · Cited by 258
New physics explanations of aμ in light of the FNAL muon g − 2 measurement
Athron, P., Balázs, C., Jacob, D. H. J., Kotlarski, W., Stöckinger, D., & Stöckinger-Kim, H. (2021) · Journal of High Energy Physics · doi:10.1007/jhep09(2021)080 · Cited by 212
Flavor probes of axion-like particles
Bauer, M., Neubert, M., Renner, S., Schnubel, M., & Thamm, A. (2022) · Journal of High Energy Physics · doi:10.1007/jhep09(2022)056 · Cited by 200
Measurement of the anomalous precession frequency of the muon in the Fermilab Muong−2Experiment
Albahri, T., Anastasi, A., Anisenkov, A., Badgley, K., Baeßler, S., Bailey, I., Baranov, V. A., Barlas-Yucel, E., Barrett, T., Basti, A., et al. (2021) · Physical Review D · doi:10.1103/physrevd.103.072002 · Cited by 189
“Recent discrepancies in the measurement of the fine structure constant [8, 9] do not significantly affect the muon g − 2 prediction.”
Background
Metadata
- Authors
- Morel, L., Yao, Z., Cladé, P., & Guellati-Khélifa, S.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- Conservatoire National des Arts et Métiers (FR)
- Corresponding author
- Guellati-Khélifa, Saïda
- Venue
- Nature
- Published
- 2020-12-02
- Volume
- 588
- Issue
- 7836
- Pages
- 61-65
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W3109247367
- Cited by
- 590
- References
- 48
- Citations by year
- 2026: 65 · 2025: 89 · 2024: 108 · 2023: 126 · 2022: 109 · 2021: 90 · 2020: 3
- FWCI
- 33.35
- Type
- journal article
- Language
- en
- Open access
- green
- hal.science
- Licence
- other-oa
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion, other-oa)
- RePEc: Research Papers in Economics (submittedVersion)
- Funders
- Agence Nationale de la Recherche (ANR-10-LABX-0048, ANR-11-EQPX-0039)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle physics theoretical and experimental studies
- Keywords
- fine-structure constant, matter-wave interferometry, rubidium atoms, electron g-factor, Standard Model tests, dark matter constraints, fundamental physical constants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of the fine-structure constant with an accuracy of 81 parts per trillion. https://app.cochat.ai/papers/10.1038/s41586-020-2964-7
- The paper
- Morel, L., Yao, Z., Cladé, P., & Guellati-Khélifa, S. (2020). Determination of the fine-structure constant with an accuracy of 81 parts per trillion. Nature. https://doi.org/10.1038/s41586-020-2964-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.