Cited by 8Mechanical and Optical ResonatorsAcoustic Wave Resonator TechnologiesAcoustic Wave Phenomena Research

Thin-film quartz for high-coherence piezoelectric phononic crystal resonators

Open access
Emser, A. L., Metzger, C., Rose, B. C., Lehnert, K. W.·2024·Physical Review Applied

Abstract

Piezoelectric phononic crystal resonators (PCRs) are a promising platform for acoustic quantum processing, yet their performance is currently limited by coupling to an ensemble of saturable two-level system (TLS) defects within the resonator material. Motivated by its excellent bulk mechanical properties and high crystallinity, we address this by fabricating PCRs using thin-film quartz as the substrate. At single-phonon powers and millikelvin temperatures---requisite conditions for quantum phononic processing---we demonstrate large internal mechanical quality factors, ${Q}_{i}>160\phantom{\rule{0.1em}{0ex}}000$. This represents an order-of-magnitude improvement in single-phonon lifetimes for piezoelectric PCR. We characterize the loss channels in these devices and find that, although improved, the low-power response is still limited by coupling to a TLS bath and that a significant portion of the TLSs are associated with the aluminum coupling electrodes. To explore the high-power response, we perform ring-down measurements and demonstrate high-power quality-factor--frequency products ${Q}_{i}\ensuremath{\cdot}f=1.4\ifmmode\times\else\texttimes\fi{}{10}^{16}$ Hz.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevapplied.22.064032

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Authors
Emser, A. L., Metzger, C., Rose, B. C., & Lehnert, K. W.
Affiliations
National Institute of Standards and Technology (US)
Corresponding author
Emser, A. L.
Venue
Physical Review Applied
Published
2024-12-10
Volume
22
Issue
6
ISSN
2331-7019 (ISSN-L)
OpenAlex
W4405238349
Cited by
8
References
1
Citations by year
2026: 3 · 2025: 4 · 2024: 1
FWCI
1.27
Type
journal article
Language
en
Open access
Locations
  • Physical Review Applied (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • arXiv (Cornell University)
Funders
  • Air Force Office of Scientific Research
  • Office of Naval Research
  • Office of the Secretary of Defense (N00014-20-1-2833)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Mechanical and Optical Resonators
  • Physical Sciences › Engineering › Biomedical Engineering › Acoustic Wave Resonator Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Acoustic Wave Phenomena Research
Keywords
two-level system defects, mechanical quality factor, millikelvin temperatures

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review