Resonant photoemission involving super-Coster-Kronig transitions
The DOI matches its Crossref record.
Abstract
We extend to photoemission the formal theory of the interaction of many discrete states with many continua and present three model calculations which illustrate the significant aspects of resonant photoemission. The first two models treat $3p$ core level to $3d$ band absorption, followed by super-Coster-Kronig decay (${3p}^{5}{3d}^{n+1}\ensuremath{\rightarrow}{3p}^{6}{3d}^{n\ensuremath{-}1}\ensuremath{\epsilon}f$), which interferes with the direct excitation of the $3d$ valence band. The first calculation is for a simple band model which applies approximately to Cr. No $d\ensuremath{-}d$ interactions or atomic effects are included, yet interference characteristic of Fano resonances is clearly evident. Specifically, a strong dip in the valence-band photoemission occurs near threshold. The second model contains hole-hole interactions and exhibits a resonant two-bound-hole satellite in photoemission. The dependence of the photoemission intensity on photon energy shows a larger Fano $q$ parameter for the satellite than for absorption, in agreement with an experiment on Ni. Further, the satellite shows strong enhancement at resonance, whereas the main line (valence-band emission) shows primarily an interference dip, as observed. The third model is for metals with filled $3d$ bands, such as Cu, Zn,.... The absorption is from $3p$ to the $4s\ensuremath{-}4p$ band. The resulting super-Coster-Kronig decay of the $3p$ hole gives rise to the ${M}_{2,3}{M}_{4,5}{M}_{4,5}$ Auger peak (fixed kinetic energy) as well as a resonant satellite at fixed binding energy. The latter is due to a singularity [$N(hv,{E}^{B})\ensuremath{\sim}{({E}^{B}\ensuremath{-}{E}_{0}^{B})}^{\ensuremath{-}\ensuremath{\lambda}}$] in the photoemission intensity caused by the strong interaction of the $4s\ensuremath{-}4p$ conduction electrons and the ${3d}^{8}$ configuration in the final state.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electronic structure of CoO, Li-doped CoO, andLiCoO2
van Elp, J., Wieland, J. L., Eskes, H., Kuiper, P., Sawatzky, G. A., de Groot, F. M. F., & Turner, T. S. (1991) · Physical Review B · doi:10.1103/physrevb.44.6090 · Cited by 665
Photoionization of atoms using synchrotron radiation
Schmidt, V (1992) · Reports on Progress in Physics · doi:10.1088/0034-4885/55/9/003 · Cited by 388
XUV spectroscopy of metal atoms
Sonntag, B., & Zimmermann, P. (1992) · Reports on Progress in Physics · doi:10.1088/0034-4885/55/7/002 · Cited by 176
Loh, Z.-H., & Leone, S. R. (2013) · The Journal of Physical Chemistry Letters · doi:10.1021/jz301910n · Cited by 66
Metadata
- Authors
- Davis, L. C., & Feldkamp, L. A.
- Venue
- Physical Review B
- Publisher
- American Physical Society (APS)
- Published
- 1981-06-15
- Volume
- 23
- Issue
- 12
- Pages
- 6239-6253
- ISSN
- 0163-1829 (ISSN-L)
- OpenAlex
- W2071980601
- Cited by
- 216
- References
- 0
- FWCI
- 26.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.