The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
X-ray diffraction studies of the structure of nanometer-sized crystalline materials
Abstract
Recently, nanometer-sized crystalline materials have been proposed to represent a new solid-state structure which exhibits neither long-range order (like crystals) nor short-range order (like glasses). It was the purpose of this study to test this idea by x-ray diffraction experiments. Nanometer-sized crystalline materials are polycrystals in which the size of the crystallites is a few (1--10) nanometers. Structurally, these materials consist of the following two components, the volume fraction of which is about 50% each: a crystalline component, formed by all atoms located in the lattice of the crystallites, and an interfacial component comprising the atoms situated in the interfaces. It is this interfacial component which was proposed to exhibit an atomic arrangement without short- or long-range order. In order to test this idea, the interference function of nanometer-sized crystalline iron (6-nm crystal size) was measured by x-ray diffraction. The measured interference function was compared with the interference function computed by assuming the interfacial component to be short-range ordered or to consist of randomly displaced atoms (no short- or long-range order). It was found that the experimental interference function can only be matched by the computed one if the interfacial component is assumed to have no short- or long-range order.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
X-ray scattering factors computed from numerical Hartree–Fock wave functions
Cromer, D. T., & Mann, J. B. (1968) · Acta Crystallographica Section A · doi:10.1107/s0567739468000550 · Cited by 3,451
Granqvist, C. G., & Buhrman, R. A. (1976) · Journal of Applied Physics · doi:10.1063/1.322870 · Cited by 1,613
Cited by
Gleiter, H. (1989) · Progress in Materials Science · doi:10.1016/0079-6425(89)90001-7 · Cited by 3,674
Self-citationA review of the electrochemical performance of alloy anodes for lithium-ion batteries
Zhang, W.-J. (2011) · Journal of Power Sources · doi:10.1016/j.jpowsour.2010.07.020 · Cited by 2,140
Nanocrystalline materials and coatings
Tjong, S. C., & Chen, H. (2004) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2004.07.001 · Cited by 928
The complete Raman spectrum of nanometric SnO2 particles
Diéguez, A., Romano-Rodrı́guez, A., Vilà, A., & Morante, J. R. (2001) · Journal of Applied Physics · doi:10.1063/1.1385573 · Cited by 843
Complex plasmas: An interdisciplinary research field
Morfill, G. E., & Ivlev, A. V. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.1353 · Cited by 803
Metadata
- Authors
- Zhu, X., Birringer, R., Herr, U., & Gleiter, H.
- Venue
- Physical Review B
- Publisher
- American Physical Society (APS)
- Published
- 1987-06-15
- Volume
- 35
- Issue
- 17
- Pages
- 9085-9090
- ISSN
- 0163-1829 (ISSN-L)
- OpenAlex
- W1980340799
- Cited by
- 418
- References
- 2
- FWCI
- 17.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: X-ray diffraction studies of the structure of nanometer-sized crystalline materials. https://app.cochat.ai/papers/10.1103/physrevb.35.9085
- The paper
- Zhu, X., Birringer, R., Herr, U., & Gleiter, H. (1987). X-ray diffraction studies of the structure of nanometer-sized crystalline materials. Physical Review B. https://doi.org/10.1103/physrevb.35.9085
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.