Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 159

The DOI matches its Crossref record.

Temperature dependence of the near-infrared refractive index of silicon, gallium arsenide, and indium phosphide

McCaulley, J. A., Donnelly, V. M., Vernon, M., Taha, I. · 1994 · Physical Review B

Abstract

Infrared laser interferometry was used to measure the temperature dependence, \ensuremath{\beta}(T), of the refractive index of Si, GaAs, and InP at \ensuremath{\lambda}=1.15, 1.31, 1.53, and 2.39 \ensuremath{\mu}m. Semiconductor wafer samples that had been polished on both sides were either heated or cooled while measuring the sample temperature and the transmitted or reflected intensity of an infrared laser beam. The changing optical path length within the material causes alternating constructive and destructive interference between reflections off the front and back surfaces of the wafer. By subtracting the contribution of thermal expansion, \ensuremath{\alpha}(T), which is small and accurately known, \ensuremath{\beta}(T) was obtained. Representative values of \ensuremath{\beta} (293 K) at 1.53 \ensuremath{\mu}m are 5.15\ifmmode\times\else\texttimes\fi{}${10}^{\mathrm{\ensuremath{-}}5}$ ${\mathrm{K}}^{\mathrm{\ensuremath{-}}1}$, 6.65\ifmmode\times\else\texttimes\fi{}${10}^{\mathrm{\ensuremath{-}}5}$ ${\mathrm{K}}^{\mathrm{\ensuremath{-}}1}$, and 5.95\ifmmode\times\else\texttimes\fi{}${10}^{\mathrm{\ensuremath{-}}5}$ ${\mathrm{K}}^{\mathrm{\ensuremath{-}}1}$ for Si, GaAs, and InP. Polynomial expressions are presented for Si, GaAs, and InP, yielding values of \ensuremath{\beta}(T) that are accurate to within \ifmmode\pm\else\textpm\fi{}5%. $beta (T)--- increases with increasing temperature and decreases with increasing wavelength. There is a large resonance enhancement of \ensuremath{\beta}(T) in direct-gap semiconductors as the photon energy ${\mathit{E}}_{\mathit{h}\ensuremath{\nu}}$ approaches the band-gap energy ${\mathit{E}}_{\mathit{g}}$. Absolute values and temperature dependences of \ensuremath{\beta} calculated from published theory agree reasonably well with the measurements. The extreme accuracy in \ensuremath{\beta} needed for interferometric thermometry, however, cannot be met by these theoretical calculations, and so requires the experimental measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevb.49.7408

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
McCaulley, J. A., Donnelly, V. M., Vernon, M., & Taha, I.
Venue
Physical Review B
Published
1994-03-15
Volume
49
Issue
11
Pages
7408-7417
ISSN
  • 0163-1829 (ISSN-L)
  • 1095-3795
OpenAlex
W2090342069
Cited by
159
References
0
FWCI
2.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.