The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Multiple wave-vector extensions of the NMR pulsed-field-gradient spin-echo diffusion measurement
Abstract
Multiple wave-vector extensions of NMR pulsed-field-gradient diffusion measurements are discussed in the context of diffractionlike effects of restricted diffusion. In the case of two independent wave vectors, it is shown that the dependence of the amplitude on the relative angle between the wave vectors carries information that is absent in the usual single-wave-vector amplitude. It is shown that a two-wave-vector measurement is sensitive to restricted diffusion even at small wave vectors, in contrast with the single-wave-vector case. It is proposed that the angular dependence noted above may be used to distinguish effects of restricted diffusion from those arising from a distribution of diffusion constants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Modified Spin-Echo Method for Measuring Nuclear Relaxation Times
Meiboom, S., & Gill, D. (1958) · Review of Scientific Instruments · doi:10.1063/1.1716296 · Cited by 6,022
Stejskal, E. O. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1696526 · Cited by 894
Restricted Self-Diffusion of Protons in Colloidal Systems by the Pulsed-Gradient, Spin-Echo Method
Tanner, J. E., & Stejskal, E. O. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670306 · Cited by 867
Diffraction-like effects in NMR diffusion studies of fluids in porous solids
Callaghan, P. T., Coy, A., MacGowan, D., Packer, K. J., & Zelaya, F. O. (1991) · Nature · doi:10.1038/351467a0 · Cited by 649
Diffusion propagator as a probe of the structure of porous media
Mitra, P. P., Sen, P. N., Schwartz, L. M., & Le Doussal, P. (1992) · Physical Review Letters · doi:10.1103/physrevlett.68.3555 · Cited by 567
Self-citationMeasurement of translational displacement probabilities by NMR: An indicator of compartmentation
Cory, D. G. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140303 · Cited by 429
Mitra, P. P., & Sen, P. N. (1992) · Physical Review B · doi:10.1103/physrevb.45.143 · Cited by 232
Self-citation
Cited by
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Compartment models of the diffusion MR signal in brain white matter: A taxonomy and comparison
Panagiotaki, E., Schneider, T., Siow, B., Hall, M. G., Lythgoe, M. F., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.081 · Cited by 422
Imaging brain microstructure with diffusion MRI: practicality and applications
Alexander, D. C., Dyrby, T. B., Nilsson, M., & Zhang, H. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3841 · Cited by 424
Novikov, D. S., Kiselev, V. G., & Jespersen, S. N. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27101 · Cited by 366
Metadata
- Authors
- Mitra, P. P.
- Venue
- Physical Review B
- Publisher
- American Physical Society (APS)
- Published
- 1995-06-01
- Volume
- 51
- Issue
- 21
- Pages
- 15074-15078
- ISSN
- 0163-1829 (ISSN-L)
- 1095-3795
- OpenAlex
- W2065539222
- Cited by
- 258
- References
- 8
- FWCI
- 0.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.