The DOI matches its Crossref record.
X-ray-absorption fine-structure standards: A comparison of experiment and theory
Abstract
The reliability of the structural parameters obtained from x-ray-absorption fine-structure (XAFS) spectra strongly depends on the quality of the standards used in the data analyses. We have compared about 30 isolated pair standards, extracted from experimental data, with those generated by the feff5 code. The absorbing atoms range from Ni (Z=28) to Pb (Z=82) and the backscattering atoms from O (Z=8) to Au (Z=79). In general, good agreement is achieved, with typical errors of 0.005 \AA{} for nearest-neighbor distances R. Significant differences are sometimes found in the backscattering amplitude F(k,R) at low values of the photoelectron wave vector k (7 A${\mathrm{\r{}}}^{\mathrm{\ensuremath{-}}1}$), especially for heavy backscattering atoms such as Au and Pt. We demonstrate that when there are significant differences between experimental and theoretical functions, F(k,R), an experimental standard, shifted from one atom pair to another, provides a better fit to the data than obtained using the theoretical standard and reduces the errors in amplitude and position, often by a factor of 2--3. The effective amplitude reduction factor ${\mathit{S}}_{\mathit{o},\mathrm{e}\mathrm{f}\mathrm{f}}^{2}$ and the ${\mathit{E}}_{\mathit{o}}$ shift for the calculated XAFS standards are also given; the former can vary by \ifmmode\pm\else\textpm\fi{}20% across the Periodic Table. Estimated experimental errors for the amplitudes are 10%, and \ensuremath{\sim}5--6 % in many cases. Some important fundamental issues, such as background removal, the influence of the energy resolution on XAFS, and correlations in the fitting parameters, are also addressed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Active sites of copper-complex catalytic materials for electrochemical carbon dioxide reduction
Weng, Z., Wu, Y., Wang, M., Jiang, J., Yang, K., Huo, S., Wang, X.-F., Ma, Q., Brudvig, G. W., Batista, V. S., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-02819-7 · Cited by 735
Gong, Q., Ding, P., Xu, M., Zhu, X., Wang, M., Deng, J., Ma, Q., Han, N., Zhu, Y., Lu, J., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-10819-4 · Cited by 678
XAFS spectroscopy; fundamental principles and data analysis
Koningsberger, D. C., Mojet, B. L., van Dorssen, G. E., & Ramaker, D. E. (2000) · Topics in Catalysis · doi:10.1023/a:1019105310221 · Cited by 520
Feng, Q., Zhao, S., Wang, Y., Dong, J., Chen, W., He, D., Wang, D., Yang, J., Zhu, Y., Zhu, H., et al. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.7b01471 · Cited by 480
Analysis of Soils and Minerals Using X‐ray Absorption Spectroscopy
Kelly, S. D., Hesterberg, D., & Ravel, B. (2008) · SSSA Book Series · doi:10.2136/sssabookser5.5.c14 · Cited by 400
X-ray Absorption Spectroscopy of Low Temperature Fuel Cell Catalysts
Russell, A. E., & Rose, A. (2004) · Chemical Reviews · doi:10.1021/cr020708r · Cited by 303
Sarma, B. B., Maurer, F., Doronkin, D. E., & Grunwaldt, J.-D. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00495 · Cited by 291
Near Infrared Optical Absorption of Gold Nanoparticle Aggregates
Norman, T. J., Grant, C. D., Magana, D., Zhang, J. Z., Liu, J., Cao, D., Bridges, F., & Van Buuren, A. (2002) · The Journal of Physical Chemistry B · doi:10.1021/jp0204197 · Cited by 259
Self-citation
Metadata
- Authors
- Li, G. G., Bridges, F., & Booth, C. H.
- Venue
- Physical Review B
- Publisher
- American Physical Society (APS)
- Published
- 1995-09-01
- Volume
- 52
- Issue
- 9
- Pages
- 6332-6348
- ISSN
- 0163-1829 (ISSN-L)
- 1095-3795
- OpenAlex
- W2088446407
- Cited by
- 225
- References
- 0
- FWCI
- 11.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.