The DOI matches its Crossref record.
Coherent phonon generation and the two stimulated Raman tensors
Abstract
We show that stimulated Raman scattering by phonons is described by two separate tensors, one of which accounts for the phonon-induced modulation of the susceptibility, and the other one for the dependence of the coherent mode amplitude on the light intensity. These tensors have the same real component, associated with impulsive generation of phonons, but different imaginary parts. If the imaginary term dominates, the mechanism for two-band processes is displacive in nature. Femtosecond pump-probe experiments on antimony, using laser energies in the range of the ${E}_{2}^{\ensuremath{'}}$ gap, support the two-tensor model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Photo-induced superconductivity
Cavalleri, A. (2018) · Contemporary Physics · doi:10.1080/00107514.2017.1406623 · Cited by 169
Metadata
- Authors
- Stevens, T. E., Kuhl, J., & Merlin, R.
- Venue
- Physical Review B
- Publisher
- American Physical Society (APS)
- Published
- 2002-03-28
- Volume
- 65
- Issue
- 14
- ISSN
- 0163-1829 (ISSN-L)
- 1095-3795
- OpenAlex
- W2019509104
- Cited by
- 308
- References
- 0
- FWCI
- 4.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coherent phonon generation and the two stimulated Raman tensors. https://app.cochat.ai/papers/10.1103/physrevb.65.144304
- The paper
- Stevens, T. E., Kuhl, J., & Merlin, R. (2002). Coherent phonon generation and the two stimulated Raman tensors. Physical Review B. https://doi.org/10.1103/physrevb.65.144304
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.