The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
X-ray image reconstruction from a diffraction pattern alone
Open accessAbstract
A solution to the inversion problem of scattering would offer aberration-free diffraction-limited three-dimensional images without the resolution and depth-of-field limitations of lens-based tomographic systems. Powerful algorithms are increasingly being used to act as lenses to form such images. Current image reconstruction methods, however, require the knowledge of the shape of the object and the low spatial frequencies unavoidably lost in experiments. Diffractive imaging has thus previously been used to increase the resolution of images obtained by other means. Here we experimentally demonstrate an inversion method, which reconstructs the image of the object without the need for any such prior knowledge.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Potential for biomolecular imaging with femtosecond X-ray pulses
Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., & Hajdu, J. (2000) · Nature · doi:10.1038/35021099 · Cited by 2,022
Cited by
Single mimivirus particles intercepted and imaged with an X-ray laser
Seibert, M. M., Ekeberg, T., Maia, F. R. N. C., Svenda, M., Andreasson, J., Jönsson, O., Odić, D., Iwan, B., Rocker, A., Westphal, D., et al. (2011) · Nature · doi:10.1038/nature09748 · Cited by 904
Self-citationThree-Dimensional Reconstruction of the Giant Mimivirus Particle with an X-Ray Free-Electron Laser
Ekeberg, T., Svenda, M., Abergel, C., Maia, F. R. N. C., Seltzer, V., Claverie, J.-M., Hantke, M., Jönsson, O., Nettelblad, C., van der Schot, G., et al. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.098102 · Cited by 344
Self-citationThree-Dimensional Visualization of a Human Chromosome Using Coherent X-Ray Diffraction
Nishino, Y., Takahashi, Y., Imamoto, N., Ishikawa, T., & Maeshima, K. (2009) · Physical Review Letters · doi:10.1103/physrevlett.102.018101 · Cited by 306
The 3D-architecture of individual free silver nanoparticles captured by X-ray scattering
Barke, I., Hartmann, H., Rupp, D., Flückiger, L., Sauppe, M., Adolph, M., Schorb, S., Bostedt, C., Treusch, R., Peltz, C., et al. (2015) · Nature Communications · doi:10.1038/ncomms7187 · Cited by 100
Watching proteins function with time-resolved x-ray crystallography
Šrajer, V., & Schmidt, M. (2017) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/aa7d32 · Cited by 67
Metadata
- Authors
- Marchesini, S., He, H., Chapman, H. N., Hau-Riege, S. P., Noy, A., Howells, M. R., Weierstall, U., & Spence, J. C. H.
- Venue
- Physical Review B
- Publisher
- American Physical Society (APS)
- Published
- 2003-10-28
- Volume
- 68
- Issue
- 14
- ISSN
- 0163-1829 (ISSN-L)
- 1095-3795
- OpenAlex
- W2002849329
- Cited by
- 883
- References
- 1
- FWCI
- 15.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: X-ray image reconstruction from a diffraction pattern alone. https://app.cochat.ai/papers/10.1103/physrevb.68.140101
- The paper
- Marchesini, S., He, H., Chapman, H. N., Hau-Riege, S. P., Noy, A., Howells, M. R., Weierstall, U., & Spence, J. C. H. (2003). X-ray image reconstruction from a diffraction pattern alone. Physical Review B. https://doi.org/10.1103/physrevb.68.140101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.