The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Three-Dimensional Visualization of a Human Chromosome Using Coherent X-Ray Diffraction
Abstract
Coherent x-ray diffraction microscopy is a lensless phase-contrast imaging technique with high image contrast. Although electron tomography allows intensive study of the three-dimensional structure of cellular organelles, it has inherent difficulty with thick objects. X rays have the unique benefit of allowing noninvasive analysis of thicker objects and high spatial resolution. We observed an unstained human chromosome using coherent x-ray diffraction. The reconstructed images in two or three dimensions show an axial structure, which has not been observed under unstained conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phase retrieval algorithms: a comparison
Fienup, J. R. (1982) · Applied Optics · doi:10.1364/ao.21.002758 · Cited by 5,596
Potential for biomolecular imaging with femtosecond X-ray pulses
Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., & Hajdu, J. (2000) · Nature · doi:10.1038/35021099 · Cited by 2,022
Miao, J., Charalambous, P., Kirz, J., & Sayre, D. (1999) · Nature · doi:10.1038/22498 · Cited by 1,976
High-Resolution Scanning X-ray Diffraction Microscopy
Thibault, P., Dierolf, M., Menzel, A., Bunk, O., David, C., & Pfeiffer, F. (2008) · Science · doi:10.1126/science.1158573 · Cited by 1,321
Henderson, R. (1995) · Quarterly Reviews of Biophysics · doi:10.1017/s003358350000305x · Cited by 1,194
Femtosecond diffractive imaging with a soft-X-ray free-electron laser
Chapman, H. N., Barty, A., Bogan, M. J., Boutet, S., Frank, M., Hau-Riege, S. P., Marchesini, S., Woods, B. W., Bajt, S., Benner, W. H., et al. (2006) · Nature Physics · doi:10.1038/nphys461 · Cited by 1,026
X-ray image reconstruction from a diffraction pattern alone
Marchesini, S., He, H., Chapman, H. N., Hau-Riege, S. P., Noy, A., Howells, M. R., Weierstall, U., & Spence, J. C. H. (2003) · Physical Review B · doi:10.1103/physrevb.68.140101 · Cited by 883
Hard-X-Ray Lensless Imaging of Extended Objects
Rodenburg, J. M., Hurst, A. C., Cullis, A. G., Dobson, B. R., Pfeiffer, F., Bunk, O., David, C., Jefimovs, K., & Johnson, I. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.034801 · Cited by 855
Soft X-ray microscopy at a spatial resolution better than 15 nm
Chao, W., Harteneck, B. D., Liddle, J. A., Anderson, E. H., & Attwood, D. T. (2005) · Nature · doi:10.1038/nature03719 · Cited by 851
Three-dimensional mapping of a deformation field inside a nanocrystal
Pfeifer, M. A., Williams, G. J., Vartanyants, I. A., Harder, R., & Robinson, I. K. (2006) · Nature · doi:10.1038/nature04867 · Cited by 697
Metadata
- Authors
- Nishino, Y., Takahashi, Y., Imamoto, N., Ishikawa, T., & Maeshima, K.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2009-01-05
- Volume
- 102
- Issue
- 1
- Pages
- 018101-018101
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1979179303
- Cited by
- 306
- References
- 25
- FWCI
- 29.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-Dimensional Visualization of a Human Chromosome Using Coherent X-Ray Diffraction. https://app.cochat.ai/papers/10.1103/physrevlett.102.018101
- The paper
- Nishino, Y., Takahashi, Y., Imamoto, N., Ishikawa, T., & Maeshima, K. (2009). Three-Dimensional Visualization of a Human Chromosome Using Coherent X-Ray Diffraction. Physical Review Letters. https://doi.org/10.1103/physrevlett.102.018101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.