The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Subwavelength imaging at optical frequencies using a transmission device formed by a periodic layered metal-dielectric structure operating in the canalization regime
Open accessAbstract
Imaging with subwavelength resolution using a periodic metal-dielectric layered structure is demonstrated. The structure operates in canalization regime as a transmission device and it does not involve negative refraction and amplification of evanescent modes. The thickness of the structure has to be an integer number of half-wavelengths and can be made as large as required for ceratin applications, in contrast to the solid metallic slabs operating with subwavelength resolution which have to be much thinner than the wavelength. Resolution of $\ensuremath{\lambda}∕20$ at $600\phantom{\rule{0.3em}{0ex}}\mathrm{nm}$ wavelength is confirmed by numerical simulation for a $300\phantom{\rule{0.3em}{0ex}}\mathrm{nm}$ thick structure formed by a periodic stack of $10\phantom{\rule{0.3em}{0ex}}\mathrm{nm}$ layers of glass with $\ensuremath{\epsilon}=2$ and $5\phantom{\rule{0.3em}{0ex}}\mathrm{nm}$ layers of metal-dielectric composite with $\ensuremath{\epsilon}=\ensuremath{-}1$. Resolution of $\ensuremath{\lambda}∕60$ is predicted for a structure with same thickness, period and operating frequency, but formed by $7.76\phantom{\rule{0.3em}{0ex}}\mathrm{nm}$ layers of silicon with $\ensuremath{\epsilon}=15$ and $7.24\phantom{\rule{0.3em}{0ex}}\mathrm{nm}$ layers of silver with $\ensuremath{\epsilon}=\ensuremath{-}14$.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Negative Refraction Makes a Perfect Lens
Pendry, J. B. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.3966 · Cited by 12,159
Cited by
Poddubny, A., Iorsh, I., Belov, P., & Kivshar, Y. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.243 · Cited by 2,156
Self-citationFar-field subdiffraction optical microscopy using metamaterial crystals: Theory and simulations
Salandrino, A., & Engheta, N. (2006) · Physical Review B · doi:10.1103/physrevb.74.075103 · Cited by 696
Hyperbolic metamaterials: new physics behind a classical problem
Drachev, V. P., Podolskiy, V. A., & Kildishev, A. V. (2013) · Optics Express · doi:10.1364/oe.21.015048 · Cited by 330
Magneto-optical metamaterials with extraordinarily strong magneto-optical effect
Luo, X., Zhou, M., Liu, J., Qiu, T., & Yu, Z. (2016) · Applied Physics Letters · doi:10.1063/1.4945051 · Cited by 33
Metadata
- Authors
- Belov, P. A., & Hao, Y.
- Venue
- Physical Review B
- Publisher
- American Physical Society (APS)
- Published
- 2006-03-17
- Volume
- 73
- Issue
- 11
- ISSN
- 1098-0121 (ISSN-L)
- 1550-235X
- OpenAlex
- W2082596215
- Cited by
- 336
- References
- 1
- FWCI
- 14.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Subwavelength imaging at optical frequencies using a transmission device formed by a periodic layered metal-dielectric structure operating in the canalization regime. https://app.cochat.ai/papers/10.1103/physrevb.73.113110
- The paper
- Belov, P. A., & Hao, Y. (2006). Subwavelength imaging at optical frequencies using a transmission device formed by a periodic layered metal-dielectric structure operating in the canalization regime. Physical Review B. https://doi.org/10.1103/physrevb.73.113110
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.