Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 562

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Diamonds with a high density of nitrogen-vacancy centers for magnetometry applications

Open access
Acosta, V. M., Bauch, E., Ledbetter, M. P., Santori, C., Fu, K.-M. C., Barclay, P. E., Beausoleil, R. G., Linget, H., Roch, J. F., Treussart, F., Chemerisov, S., Gawlik, W., Budker, D.·2009·Physical Review B

Abstract

Nitrogen-vacancy (NV) centers in millimeter-scale diamond samples were produced by irradiation and subsequent annealing under varied conditions. The optical and spin-relaxation properties of these samples were characterized using confocal microscopy, visible and infrared absorption, and optically detected magnetic resonance. The sample with the highest ${\text{NV}}^{\ensuremath{-}}$ concentration, approximately 16 ppm $(2.8\ifmmode\times\else\texttimes\fi{}{10}^{18}\text{ }{\text{cm}}^{\ensuremath{-}3})$, was prepared with no observable traces of neutrally charged vacancy defects. The effective transverse spin-relaxation time for this sample was ${T}_{2}^{\ensuremath{\ast}}=118(48)\text{ }\text{ns}$, predominately limited by residual paramagnetic nitrogen which was determined to have a concentration of 49(7) ppm. Under ideal conditions, the shot-noise limited sensitivity is projected to be $\ensuremath{\sim}150\text{ }\text{fT}/\sqrt{\text{Hz}}$ for a $100\text{ }\ensuremath{\mu}\text{m}$-scale magnetometer based on this sample. Other samples with ${\text{NV}}^{\ensuremath{-}}$ concentrations from 0.007 to 12 ppm and effective relaxation times ranging from 27 to over 291 ns were prepared and characterized.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevb.80.115202

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 562

Metadata

Authors
Acosta, V. M., Bauch, E., Ledbetter, M. P., Santori, C., Fu, K.-M. C., Barclay, P. E., Beausoleil, R. G., Linget, H., Roch, J. F., Treussart, F., Chemerisov, S., Gawlik, W., & Budker, D.
Venue
Physical Review B
Published
2009-09-09
Volume
80
Issue
11
ISSN
  • 1098-0121 (ISSN-L)
  • 1550-235X
OpenAlex
W1889184373
Cited by
562
References
3
FWCI
7.18
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diamonds with a high density of nitrogen-vacancy centers for magnetometry applications. https://app.cochat.ai/papers/10.1103/physrevb.80.115202
The paper
Acosta, V. M., Bauch, E., Ledbetter, M. P., Santori, C., Fu, K.-M. C., Barclay, P. E., Beausoleil, R. G., Linget, H., Roch, J. F., Treussart, F., Chemerisov, S., Gawlik, W., & Budker, D. (2009). Diamonds with a high density of nitrogen-vacancy centers for magnetometry applications. Physical Review B. https://doi.org/10.1103/physrevb.80.115202

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.