Electron magnetic moment from geonium spectra: Early experiments and background concepts
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The magnetic moment of a free electron has been measured by observing both its low-energy spin and cyclotron resonances (at ${\ensuremath{\nu}}_{s}$=${\ensuremath{\omega}}_{s}$/2\ensuremath{\pi} and ${\ensuremath{\nu}}_{c}$=${\ensuremath{\omega}}_{c}$/2\ensuremath{\pi}, respectively) by means of a sensitive frequency-shift technique. Using radiation and tuned-circuit damping of a single electron, isolated in a special anharmonicity-compensated Penning trap, also cooled to 4 K, the electron's motion is brought nearly to rest, thus preparing it in a cold quasipermanent state of the geonium ``atom.'' The magnetic-coupling scheme, described as a continuous Stern-Gerlach effect, is made possible through a weak Lawrence magnetic bottle which causes the very narrow axial resonance, at ${\ensuremath{\nu}}_{z}$=${\ensuremath{\omega}}_{z}$/2\ensuremath{\pi} for the harmonically bound electron, to change in frequency by a small fixed amount \ensuremath{\delta} per unit change in magnetic quantum number.Spin flips are indirectly induced by a scheme which weakly drives the axial motion at the ${\ensuremath{\nu}}_{a}$=${\ensuremath{\omega}}_{a}$/2\ensuremath{\pi} spin-cyclotron difference frequency within the inhomogeneous magnetic field, thus yielding a measure of ${\ensuremath{\omega}}_{a}$\ensuremath{\equiv}${\ensuremath{\omega}}_{s}$-${\ensuremath{\omega}}_{c}$. The magnetic moment ${\ensuremath{\mu}}_{s}$ in terms of the Bohr magneton ${\ensuremath{\mu}}_{B}$ equals (1/2) the spin's g factor, which in turn is described by ${\ensuremath{\omega}}_{s}$ and ${\ensuremath{\omega}}_{c}$: g=2${\ensuremath{\mu}}_{s}$/${\ensuremath{\mu}}_{B}$=2${\ensuremath{\omega}}_{s}$/${\ensuremath{\omega}}_{c}$. In a Penning trap, however, these resonance frequencies are obtained from the observed cyclotron frequency at ${\ensuremath{\omega}}_{c}^{\mathcal{'}}$=${\ensuremath{\omega}}_{c}$-${\ensuremath{\delta}}_{e}$ and the observed anomaly frequency at ${\ensuremath{\omega}}_{a}^{\mathcal{'}}$=${\ensuremath{\omega}}_{s}$-${\ensuremath{\omega}}_{c}^{\mathcal{'}}$, which are related by the small electric shift ${\ensuremath{\delta}}_{e}$ computed using the measured axial frequency and 2${\ensuremath{\delta}}_{e}$${\ensuremath{\omega}}_{c}^{\mathcal{'}}$=${\ensuremath{\omega}}_{z}$${\mathrm{}}^{2}$. This last expression, derived for a perfectly axially symmetric trap, happens to be practically invariant against small imperfections in the electric quadrupole field (error in ${\ensuremath{\omega}}_{c}$${<10}^{\mathrm{\ensuremath{-}}16}$). The magnetic-bottle-determined line shapes are analyzed and found to have sharp low-frequency edge features which correspond to the electron being temporarily at the trap center and at the bottom of the magnetic well. Relativistic shifts are considered and found to be ${<10}^{\mathrm{\ensuremath{-}}11}$. Our result at the time of submission, g/2=1.001 159 652 200 (40), is the most accurately determined parameter of any elementary charged particle which in addition can be directly compared with theory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of the stored ion calorimeter
Wineland, D. J., & Dehmelt, H. G. (1975) · Journal of Applied Physics · doi:10.1063/1.321602 · Cited by 328
Self-citationOn the Zitterbewegung of the Dirac Electron
Huang, K. (1952) · American Journal of Physics · doi:10.1119/1.1933296 · Cited by 226
Bolometric technique for the RF spectroscopy of stored ions
Dehmelt, H. G., & Walls, F. L. (1968) · Physical Review Letters · doi:10.1103/physrevlett.21.127 · Cited by 165
Self-citationContinuous Stern-Gerlach effect: Principle and idealized apparatus
Dehmelt, H. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.8.2291 · Cited by 115
Self-citationHigh mass resolution with a new variable anharmonicity Penning trap
Van Dyck, R. S., Wineland, D. J., Ekstrom, P. A., & Dehmelt, H. G. (1976) · Applied Physics Letters · doi:10.1063/1.88793 · Cited by 87
Self-citation
Cited by
CODATA recommended values of the fundamental physical constants: 2010
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2012) · Reviews of Modern Physics · doi:10.1103/revmodphys.84.1527 · Cited by 2,441
Lorentz-violating extension of the standard model
Colladay, D., & Kostelecký, V. A. (1998) · Physical Review D · doi:10.1103/physrevd.58.116002 · Cited by 2,403
Fabian, J., Matos-Abiague, A., Ertler, C., Stano, P., & Žutić, I. (2007) · Acta Physica Slovaca. Reviews and Tutorials · doi:10.2478/v10155-010-0086-8 · Cited by 798
CODATA recommended values of the fundamental physical constants: 1998
Mohr, P. J., & Taylor, B. N. (2000) · Reviews of Modern Physics · doi:10.1103/revmodphys.72.351 · Cited by 768
New high-precision comparison of electron and positron g factors
Van Dyck, R. S., Schwinberg, P. B., & Dehmelt, H. G. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.26 · Cited by 659
Self-citationConstraints on Lorentz violation from clock-comparison experiments
Kostelecký, V. A., & Lane, C. D. (1999) · Physical Review D · doi:10.1103/physrevd.60.116010 · Cited by 378
Experiments with an isolated subatomic particle at rest
Dehmelt, H. (1990) · Reviews of Modern Physics · doi:10.1103/revmodphys.62.525 · Cited by 302
Self-citationMilestones in fourier transform ion cyclotron resonance mass spectrometry technique development
Marshall, A. G. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00324-9 · Cited by 295
CPTand Lorentz tests in Penning traps
Bluhm, R., Kostelecký, V. A., & Russell, N. (1998) · Physical Review D · doi:10.1103/physrevd.57.3932 · Cited by 245
CPTand Lorentz Tests with Muons
Bluhm, R., Kostelecký, V. A., & Lane, C. D. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.1098 · Cited by 237
Single-electron transfer in metallic nanostructures
Devoret, M. H., Esteve, D., & Urbina, C. (1992) · Nature · doi:10.1038/360547a0 · Cited by 218
Lorentz andCPTTests with Spin-Polarized Solids
Bluhm, R., & Kostelecký, V. A. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.1381 · Cited by 201
Fourier transform ion cyclotron resonance (FT ICR) mass spectrometry: Theory and simulations
Nikolaev, E. N., Kostyukevich, Y. I., & Vladimirov, G. N. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21422 · Cited by 201
Past Electron-Positrong−2Experiments Yielded Sharpest Bound onCPTViolation for Point Particles
Dehmelt, H., Mittleman, R., Van Dyck, R. S., & Schwinberg, P. (1999) · Physical Review Letters · doi:10.1103/physrevlett.83.4694 · Cited by 191
Self-citation
Metadata
- Authors
- Van Dyck, R. S., Schwinberg, P. B., & Dehmelt, H. G.
- Venue
- Physical Review D
- Publisher
- American Physical Society (APS)
- Published
- 1986-08-01
- Volume
- 34
- Issue
- 3
- Pages
- 722-736
- ISSN
- 0556-2821 (ISSN-L)
- OpenAlex
- W2069962254
- Cited by
- 124
- References
- 5
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.