Modeling the effects of anesthesia on the electroencephalogram
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Changes to the electroencephalogram (EEG) observed during general anesthesia are modeled with a physiological mean field theory of electrocortical activity. To this end a parametrization of the postsynaptic impulse response is introduced which takes into account pharmacological effects of anesthetic agents on neuronal ligand-gated ionic channels. Parameter sets for this improved theory are then identified which respect known anatomical constraints and predict mean firing rates and power spectra typically encountered in human subjects. Through parallelized simulations of the eight nonlinear, two-dimensional partial differential equations on a grid representing an entire human cortex, it is demonstrated that linear approximations are sufficient for the prediction of a range of quantitative EEG variables. More than 70,000 plausible parameter sets are finally selected and subjected to a simulated induction with the stereotypical inhaled general anesthetic isoflurane. Thereby 86 parameter sets are identified that exhibit a strong "biphasic" rise in total power, a feature often observed in experiments. A sensitivity study suggests that this "biphasic" behavior is distinguishable even at low agent concentrations. Finally, our results are briefly compared with previous work by other groups and an outlook on future fits to experimental data is provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1982) · Trends in Neurosciences · doi:10.1016/0166-2236(82)90076-5 · Cited by 9,089
Electric Fields of the Brain: The Neurophysics of EEG
Nunez, P. L., & Harth, E. (1982) · Physics Today · doi:10.1063/1.2915137 · Cited by 2,232
Electric Fields of the Brain: The Neurophysics of EEG
Fermaglich, J. (1982) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1982.03320380071046 · Cited by 1,543
A Primer for EEG Signal Processing in Anesthesia
Rampil, I. J. (1998) · Anesthesiology · doi:10.1097/00000542-199810000-00023 · Cited by 1,503
Myles, P., Leslie, K., McNeil, J., Forbes, A., & Chan, M. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16300-9 · Cited by 1,301
Neocortical Dynamics and Human EEG Rhythms
Collura, T. F. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199603000-00010 · Cited by 892
Simulation of chaotic EEG patterns with a dynamic model of the olfactory system
Freeman, W. J. (1987) · Biological Cybernetics · doi:10.1007/bf00317988 · Cited by 828
Molecular and neuronal substrates for general anaesthetics
Rudolph, U., & Antkowiak, B. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1496 · Cited by 772
Rothwell, J. (1982) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.45.5.476 · Cited by 744
Field Theory of Electromagnetic Brain Activity
Jirsa, V. K., & Haken, H. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.960 · Cited by 480
Cited by
Dynamic models of large-scale brain activity
Breakspear, M. (2017) · Nature Neuroscience · doi:10.1038/nn.4497 · Cited by 1,239
“These models have found broad success in modeling seizures 11 , encephalopathies 12,13 , sleep 14 , anesthesia 15 , resting-state brain networks 16,17 and the human alpha rhythm 18,19 , and as a tool for multimodal data fusion 20 .”
MethodMathematical framework for large-scale brain network modeling in The Virtual Brain
Sanz-Leon, P., Knock, S. A., Spiegler, A., & Jirsa, V. K. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.01.002 · Cited by 356
“…and quantitatively, a range of physiological effects, for example: the effect of anesthesia (Steyn-Ross et al., 1999; Foster et al., 2008; Bojak and Liley, 2005; Steyn-Ross et al., 2003; Liley and Walsh, 2013; Liley and Bojak, 2005); the influence of thalamic inputs (Robinson et al.,…”
InfluentialLarge-scale neural dynamics: Simple and complex
Coombes, S. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.01.045 · Cited by 165
“There are a number of natural extensions to neural field models to incorporate ever more biological realism, including the incorporation of slow intrinsic currents that underlie bursting behaviour in single neurons [86, 11], synaptic depression and adaptation [87], dendritic processing [61], neuromodulation, say by en…”
Background
Metadata
- Authors
- Bojak, I., & Liley, D. T. J.
- Venue
- Physical Review E
- Publisher
- American Physical Society (APS)
- Published
- 2005-04-04
- Volume
- 71
- Issue
- 4
- Pages
- 041902-041902
- ISSN
- 1539-3755 (ISSN-L)
- 1550-2376
- OpenAlex
- W2038141274
- Cited by
- 185
- References
- 42
- FWCI
- 3.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Modeling the effects of anesthesia on the electroencephalogram. https://app.cochat.ai/papers/10.1103/physreve.71.041902
- The paper
- Bojak, I., & Liley, D. T. J. (2005). Modeling the effects of anesthesia on the electroencephalogram. Physical Review E. https://doi.org/10.1103/physreve.71.041902
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.