Label-free DNA sensors using ultrasensitive diamond field-effect transistors in solution
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Charge detection biosensors have recently become the focal point of biosensor research, especially field-effect-transistors (FETs) that combine compactness, low cost, high input, and low output impedances, to realize simple and stable in vivo diagnostic systems. However, critical evaluation of the possibility and limitations of charge detection of label-free DNA hybridization using silicon-based ion-sensitive FETs (ISFETs) has been introduced recently. The channel surface of these devices must be covered by relatively thick insulating layers ( SiO2, Si3N4, Al2O3, or Ta2O5) to protect against the invasion of ions from solution. These thick insulating layers are not suitable for charge detection of DNA and miniaturization, as the small capacitance of thick insulating layers restricts translation of the negative DNA charge from the electrolyte to the channel surface. To overcome these difficulties, thin-gate-insulator FET sensors should be developed. Here, we report diamond solution-gate FETs (SGFETs), where the DNA-immobilized channels are exposed directly to the electrolyte solution without gate insulator. These SGFETs operate stably within the large potential window of diamond (>3.0 V). Thus, the channel surface does not need to be covered by thick insulating layers, and DNA is immobilized directly through amine sites, which is a factor of 30 more sensitive than existing Si-ISFET DNA sensors. Diamond SGFETs can rapidly detect complementary, 3-mer mismatched (10 pM) and has a potential for the detection of single-base mismatched oligonucleotide DNA, without biological degradation by cyclically repeated hybridization and denature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Cited by
Detection principles of biological and chemical FET sensors
Kaisti, M. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.010 · Cited by 577
Conductive diamond: synthesis, properties, and electrochemical applications
Yang, N., Yu, S., Macpherson, J. V., Einaga, Y., Zhao, H., Zhao, G., Swain, G. M., & Jiang, X. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00757d · Cited by 522
Ion-Sensitive Field-Effect Transistor for Biological Sensing
Lee, C.-S., Kim, S. K., & Kim, M. (2009) · Sensors · doi:10.3390/s90907111 · Cited by 426
Dual‐Gate Organic Field‐Effect Transistors as Potentiometric Sensors in Aqueous Solution
Spijkman, M., Brondijk, J. J., Geuns, T. C. T., Smits, E. C. P., Cramer, T., Zerbetto, F., Stoliar, P., Biscarini, F., Blom, P. W. M., & de Leeuw, D. M. (2010) · Advanced Functional Materials · doi:10.1002/adfm.200901830 · Cited by 154
Beyond the Nernst-limit with dual-gate ZnO ion-sensitive field-effect transistors
Spijkman, M., Smits, E. C. P., Cillessen, J. F. M., Biscarini, F., Blom, P. W. M., & de Leeuw, D. M. (2011) · Applied Physics Letters · doi:10.1063/1.3546169 · Cited by 135
Metadata
- Authors
- Song, K.-S., Zhang, G.-J., Nakamura, Y., Furukawa, K., Hiraki, T., Yang, J.-H., Funatsu, T., Ohdomari, I., & Kawarada, H.
- Venue
- Physical Review E
- Publisher
- American Physical Society (APS)
- Published
- 2006-10-27
- Volume
- 74
- Issue
- 4
- Pages
- 041919-041919
- ISSN
- 1539-3755 (ISSN-L)
- 1550-2376
- OpenAlex
- W2039345857
- Cited by
- 104
- References
- 1
- FWCI
- 5.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Label-free DNA sensors using ultrasensitive diamond field-effect transistors in solution. https://app.cochat.ai/papers/10.1103/physreve.74.041919
- The paper
- Song, K.-S., Zhang, G.-J., Nakamura, Y., Furukawa, K., Hiraki, T., Yang, J.-H., Funatsu, T., Ohdomari, I., & Kawarada, H. (2006). Label-free DNA sensors using ultrasensitive diamond field-effect transistors in solution. Physical Review E. https://doi.org/10.1103/physreve.74.041919
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.