The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Reconstruction algorithm for single-particle diffraction imaging experiments
Open accessAbstract
We introduce the EMC algorithm for reconstructing a particle's three-dimensional (3D) diffraction intensity from very many photon shot-noise limited two-dimensional measurements, when the particle orientation in each measurement is unknown. The algorithm combines a maximization step (M) of the intensity's likelihood function, with expansion (E) and compression (C) steps that map the 3D intensity model to a redundant tomographic representation and back again. After a few iterations of the EMC update rule, the reconstructed intensity is given to the difference-map algorithm for reconstruction of the particle contrast. We demonstrate reconstructions with simulated data and investigate the effects of particle complexity, number of measurements, and the number of photons per measurement. The relatively transparent scaling behavior of our algorithm provides an estimate of the data processing resources required for future single-particle imaging experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
Potential for biomolecular imaging with femtosecond X-ray pulses
Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., & Hajdu, J. (2000) · Nature · doi:10.1038/35021099 · Cited by 2,022
Biological imaging by soft x-ray diffraction microscopy
Shapiro, D., Thibault, P., Beetz, T., Elser, V., Howells, M., Jacobsen, C., Kirz, J., Lima, E., Miao, H., Neiman, A. M., et al. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503305102 · Cited by 554
Self-citationDisentangling conformational states of macromolecules in 3D-EM through likelihood optimization
Scheres, S. H. W., Gao, H., Valle, M., Herman, G. T., Eggermont, P. P. B., Frank, J., & Carazo, J.-M. (2007) · Nature Methods · doi:10.1038/nmeth992 · Cited by 407
Dynamics of biological molecules irradiated by short x-ray pulses
Hau-Riege, S. P., London, R. A., & Szoke, A. (2004) · Physical Review E · doi:10.1103/physreve.69.051906 · Cited by 216
Structure from fleeting illumination of faint spinning objects in flight
Fung, R., Shneerson, V., Saldin, D. K., & Ourmazd, A. (2009) · Nature Physics · doi:10.1038/nphys1129 · Cited by 184
Diffraction imaging of single particles and biomolecules
Huldt, G., Szőke, A., & Hajdu, J. (2003) · Journal of Structural Biology · doi:10.1016/j.jsb.2003.09.025 · Cited by 177
Dynamical diffraction of ultrashort X-ray free-electron laser pulses
Shastri, S. D., Zambianchi, P., & Mills, D. M. (2001) · Journal of Synchrotron Radiation · doi:10.1107/s0909049501012390 · Cited by 61
X-ray tests of a Pixel Array Detector for coherent x-ray imaging at the Linac Coherent Light Source
Koerner, L. J., Philipp, H. T., Hromalik, M. S., Täte, M. W., & Gruner, S. M. (2009) · Journal of Instrumentation · doi:10.1088/1748-0221/4/03/p03001 · Cited by 46
Noise Limits on Reconstructing Diffraction Signals From Random Tomographs
Elser, V. (2009) · IEEE Transactions on Information Theory · doi:10.1109/tit.2009.2027547 · Cited by 31
Self-citationClassification of continuous diffraction patterns: A numerical study
Bortel, G., & Faigel, G. (2006) · Journal of Structural Biology · doi:10.1016/j.jsb.2006.10.018 · Cited by 28
Cited by
Femtosecond X-ray protein nanocrystallography
Chapman, H. N., Fromme, P., Barty, A., White, T. A., Kirian, R. A., Aquila, A., Hunter, M. S., Schulz, J., DePonte, D. P., Weierstall, U., et al. (2011) · Nature · doi:10.1038/nature09750 · Cited by 2,086
Single mimivirus particles intercepted and imaged with an X-ray laser
Seibert, M. M., Ekeberg, T., Maia, F. R. N. C., Svenda, M., Andreasson, J., Jönsson, O., Odić, D., Iwan, B., Rocker, A., Westphal, D., et al. (2011) · Nature · doi:10.1038/nature09748 · Cited by 904
Beyond crystallography: Diffractive imaging using coherent x-ray light sources
Miao, J., Ishikawa, T., Robinson, I. K., & Murnane, M. M. (2015) · Science · doi:10.1126/science.aaa1394 · Cited by 808
Linac Coherent Light Source: The first five years
Bostedt, C., Boutet, S., Fritz, D. M., Huang, Z., Lee, H. J., Lemke, H. T., Robert, A., Schlotter, W. F., Turner, J. J., & Williams, G. J. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.015007 · Cited by 618
Three-Dimensional Reconstruction of the Giant Mimivirus Particle with an X-Ray Free-Electron Laser
Ekeberg, T., Svenda, M., Abergel, C., Maia, F. R. N. C., Seltzer, V., Claverie, J.-M., Hantke, M., Jönsson, O., Nettelblad, C., van der Schot, G., et al. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.098102 · Cited by 344
Self-citation
Metadata
- Authors
- Loh, N.-T. D., & Elser, V.
- Venue
- Physical Review E
- Publisher
- American Physical Society (APS)
- Published
- 2009-08-24
- Volume
- 80
- Issue
- 2
- Pages
- 026705-026705
- ISSN
- 1539-3755 (ISSN-L)
- 1550-2376
- OpenAlex
- W1988662633
- Cited by
- 292
- References
- 11
- FWCI
- 14.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.