CoChat

Electric double-layer potentials and surface regulation properties measured by colloidal-probe atomic force microscopy

Open access
Montes Ruiz-Cabello, F. Javier, Trefalt, Gregor, Maroni, Plinio, Borkovec, Michal · 2014 · Physical Review E
Cited by 60

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

We show how the colloidal-probe technique, which is based on force measurements made with the atomic force microscope, can be used to accurately determine the charging parameters of water-solid interfaces. Besides yielding accurate values of the double-layer or diffuse-layer potential, the method also allows reliable determination of the charge regulation properties of the surfaces. The latter can be quantified with a regulation parameter, which is essential to properly describe forces between interfaces, especially in asymmetric situations when one of the interfaces is charged and the other one is close to neutral. The technique relies on a highly charged probe particle, for which the charging properties are accurately determined by interpreting the double-layer contribution of the measured force profiles in the symmetric sphere-sphere geometry with Poisson-Boltzmann (PB) theory. Once the probe particle is calibrated, this particle is used to measure the force profile between an unknown substrate in the asymmetric sphere-sphere or sphere-plane geometry. From this profile, the diffuse-layer potential and regulation parameter of the substrate can be again determined with PB theory. The technique is highly versatile, as it can be used for a wide variety of substrates, including colloidal particles and planar substrates. The technique is also applicable in salt solutions containing multivalent ions. The current drawbacks of the technique are that it can only be applied up to moderately high salt levels, typically to 10 mM, and only for relatively large particles, typically down to about 1 μm in diameter. How the technique could be extended to higher salt levels and smaller particle size is also briefly discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physreve.90.012301

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 60

Metadata

Authors
Montes Ruiz-Cabello, F. J., Trefalt, G., Maroni, P., & Borkovec, M.
Venue
Physical Review E
Published
2014-07-02
Volume
90
Issue
1
Pages
012301-012301
ISSN
  • 1539-3755 (ISSN-L)
  • 1550-2376
OpenAlex
W2333041227
Cited by
60
References
1
FWCI
3.64
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electric double-layer potentials and surface regulation properties measured by colloidal-probe atomic force microscopy. https://app.cochat.ai/papers/10.1103/physreve.90.012301
The paper
Montes Ruiz-Cabello, F. J., Trefalt, G., Maroni, P., & Borkovec, M. (2014). Electric double-layer potentials and surface regulation properties measured by colloidal-probe atomic force microscopy. Physical Review E. https://doi.org/10.1103/physreve.90.012301

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.