The DOI matches its Crossref record.
Sensing of Fluctuating Nanoscale Magnetic Fields Using Nitrogen-Vacancy Centers in Diamond
Open accessAbstract
New magnetometry techniques based on nitrogen-vacancy (NV) defects in diamond allow for the detection of static (dc) and oscillatory (ac) nanoscopic magnetic fields, yet are limited in their ability to detect fields arising from randomly fluctuating (FC) environments. We show here that FC fields restrict dc and ac sensitivities and that probing the NV dephasing rate in a FC environment should permit the characterization of FC fields inaccessible to dc and ac techniques. FC sensitivities are shown to be comparable to those of ac magnetometry and require no additional experimental overhead or sample control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The nitrogen-vacancy colour centre in diamond
Doherty, M. W., Manson, N. B., Delaney, P., Jelezko, F., Wrachtrup, J., & Hollenberg, L. C. L. (2013) · Physics Reports · doi:10.1016/j.physrep.2013.02.001 · Cited by 2,866
Self-citationMagnetometry with nitrogen-vacancy defects in diamond
Rondin, L., Tetienne, J.-P., Hingant, T., Roch, J.-F., Maletinsky, P., & Jacques, V (2014) · Reports on Progress in Physics · doi:10.1088/0034-4885/77/5/056503 · Cited by 1,336
Electric-field sensing using single diamond spins
Dolde, F., Fedder, H., Doherty, M. W., Nöbauer, T., Rempp, F., Balasubramanian, G., Wolf, T., Reinhard, F., Hollenberg, L. C. L., Jelezko, F., et al. (2011) · Nature Physics · doi:10.1038/nphys1969 · Cited by 1,334
Self-citationNuclear Magnetic Resonance Spectroscopy on a (5-Nanometer) 3 Sample Volume
Staudacher, T., Shi, F., Pezzagna, S., Meijer, J., Du, J., Meriles, C. A., Reinhard, F., & Wrachtrup, J. (2013) · Science · doi:10.1126/science.1231675 · Cited by 754
Quantum measurement and orientation tracking of fluorescent nanodiamonds inside living cells
McGuinness, L. P., Yan, Y., Stacey, A., Simpson, D. A., Hall, L. T., Maclaurin, D., Prawer, S., Mulvaney, P., Wrachtrup, J., Caruso, F., et al. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.64 · Cited by 666
Self-citation
Metadata
- Authors
- Hall, L. T., Cole, J. H., Hill, C. D., & Hollenberg, L. C. L.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2009-11-25
- Volume
- 103
- Issue
- 22
- Pages
- 220802-220802
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1517719264
- Cited by
- 159
- References
- 0
- FWCI
- 4.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensing of Fluctuating Nanoscale Magnetic Fields Using Nitrogen-Vacancy Centers in Diamond. https://app.cochat.ai/papers/10.1103/physrevlett.103.220802
- The paper
- Hall, L. T., Cole, J. H., Hill, C. D., & Hollenberg, L. C. L. (2009). Sensing of Fluctuating Nanoscale Magnetic Fields Using Nitrogen-Vacancy Centers in Diamond. Physical Review Letters. https://doi.org/10.1103/physrevlett.103.220802
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.