The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Quantum Metrology with Two-Mode Squeezed Vacuum: Parity Detection Beats the Heisenberg Limit
Open accessAbstract
We study the sensitivity and resolution of phase measurement in a Mach-Zehnder interferometer with two-mode squeezed vacuum (n photons on average). We show that superresolution and sub-Heisenberg sensitivity is obtained with parity detection. In particular, in our setup, dependence of the signal on the phase evolves n times faster than in traditional schemes, and uncertainty in the phase estimation is better than 1/n, and we saturate the quantum Cramer-Rao bound.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum-mechanical noise in an interferometer
Caves, C. M. (1981) · Physical Review D · doi:10.1103/physrevd.23.1693 · Cited by 3,202
Statistical distance and the geometry of quantum states
Braunstein, S. L., & Caves, C. M. (1994) · Physical Review Letters · doi:10.1103/physrevlett.72.3439 · Cited by 3,176
Giovannetti, V., Lloyd, S., & Maccone, L. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.010401 · Cited by 2,440
Quantum optical metrology – the lowdown on high-N00N states
Dowling, J. P. (2008) · Contemporary Physics · doi:10.1080/00107510802091298 · Cited by 894
Self-citationCounting near-infrared single-photons with 95% efficiency
Lita, A. E., Miller, A. J., & Nam, S. W. (2008) · Optics Express · doi:10.1364/oe.16.003032 · Cited by 734
Cited by
Quantum metrology with entangled coherent states
Joo, J., Munro, W. J., & Spiller, T. P. (2011) · Physical Review Letters · doi:10.1103/physrevlett.107.083601 · Cited by 526
Quantum Limits in Optical Interferometry
Demkowicz-Dobrzański, R., Jarzyna, M., & Kołodyński, J. (2015) · Progress in Optics · doi:10.1016/bs.po.2015.02.003 · Cited by 517
An entanglement-enhanced microscope
Ono, T., Okamoto, R., & Takeuchi, S. (2013) · Nature Communications · doi:10.1038/ncomms3426 · Cited by 323
Quantum metrology for a general Hamiltonian parameter
Pang, S., & Brun, T. A. (2014) · Physical Review A · doi:10.1103/physreva.90.022117 · Cited by 175
Ziv–Zakai error bounds for quantum parameter estimation
Tsang, M. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.230401 · Cited by 137
Metadata
- Authors
- Anisimov, P. M., Raterman, G. M., Chiruvelli, A., Plick, W. N., Huver, S. D., Lee, H., & Dowling, J. P.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2010-03-12
- Volume
- 104
- Issue
- 10
- Pages
- 103602-103602
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2033225070
- Cited by
- 449
- References
- 5
- FWCI
- 18.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantum Metrology with Two-Mode Squeezed Vacuum: Parity Detection Beats the Heisenberg Limit. https://app.cochat.ai/papers/10.1103/physrevlett.104.103602
- The paper
- Anisimov, P. M., Raterman, G. M., Chiruvelli, A., Plick, W. N., Huver, S. D., Lee, H., & Dowling, J. P. (2010). Quantum Metrology with Two-Mode Squeezed Vacuum: Parity Detection Beats the Heisenberg Limit. Physical Review Letters. https://doi.org/10.1103/physrevlett.104.103602
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.