The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Low-Emittance Electron Bunches from a Laser-Plasma Accelerator Measured using Single-Shot X-Ray Spectroscopy
Abstract
X-ray spectroscopy is used to obtain single-shot information on electron beam emittance in a low-energy-spread 0.5 GeV-class laser-plasma accelerator. Measurements of betatron radiation from 2 to 20 keV used a CCD and single-photon counting techniques. By matching x-ray spectra to betatron radiation models, the electron bunch radius inside the plasma is estimated to be ~0.1 μm. Combining this with simultaneous electron spectra, normalized transverse emittance is estimated to be as low as 0.1 mm mrad, consistent with three-dimensional particle-in-cell simulations. Correlations of the bunch radius with electron beam parameters are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tajima, T., & Dawson, J. M. (1979) · Physical Review Letters · doi:10.1103/physrevlett.43.267 · Cited by 4,705
A laser–plasma accelerator producing monoenergetic electron beams
Faure, J., Glinec, Y., Pukhov, A., Kiselev, S., Gordienko, S., Lefebvre, E., Rousseau, J.-P., Burgy, F., & Malka, V. (2004) · Nature · doi:10.1038/nature02963 · Cited by 2,129
High-quality electron beams from a laser wakefield accelerator using plasma-channel guiding
Geddes, C. G. R., Toth, C., van Tilborg, J., Esarey, E., Schroeder, C. B., Bruhwiler, D., Nieter, C., Cary, J., & Leemans, W. P. (2004) · Nature · doi:10.1038/nature02900 · Cited by 2,001
Self-citationMonoenergetic beams of relativistic electrons from intense laser–plasma interactions
Mangles, S. P. D., Murphy, C. D., Najmudin, Z., Thomas, A. G. R., Collier, J. L., Dangor, A. E., Divall, E. J., Foster, P. S., Gallacher, J. G., Hooker, C. J., et al. (2004) · Nature · doi:10.1038/nature02939 · Cited by 1,977
VORPAL: a versatile plasma simulation code
Nieter, C., & Cary, J. R. (2004) · Journal of Computational Physics · doi:10.1016/j.jcp.2003.11.004 · Cited by 667
Leemans, W. P., Geddes, C. G. R., Faure, J., Tóth, C., van Tilborg, J., Schroeder, C. B., Esarey, E., Fubiani, G., Auerbach, D., Marcelis, B., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.074802 · Cited by 377
Self-citation
Cited by
Developments in laser-driven plasma accelerators
Hooker, S. M. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.234 · Cited by 345
Applications of laser wakefield accelerator-based light sources
Albert, F., & Thomas, A. G. R. (2016) · Plasma Physics and Controlled Fusion · doi:10.1088/0741-3335/58/10/103001 · Cited by 314
Döpp, A., Guillaume, E., Thaury, C., Lifschitz, A., Sylla, F., Goddet, J.-P., Tafzi, A., Iaquanello, G., Lefrou, T., Rousseau, P., et al. (2016) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2016.01.086 · Cited by 280
Metadata
- Authors
- Plateau, G. R., Geddes, C. G. R., Thorn, D. B., Chen, M., Benedetti, C., Esarey, E., Gonsalves, A. J., Matlis, N. H., Nakamura, K., Schroeder, C. B., Shiraishi, S., Sokollik, T., van Tilborg, J., Toth, C., Trotsenko, S., Kim, T. S., Battaglia, M., Stöhlker, T., & Leemans, W. P.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2012-08-10
- Volume
- 109
- Issue
- 6
- Pages
- 064802-064802
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2318441764
- Cited by
- 183
- References
- 6
- FWCI
- 8.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.