The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Current-Induced Membrane Discharge
Open accessAbstract
Possible mechanisms for overlimiting current (OLC) through aqueous ion-exchange membranes (exceeding diffusion limitation) have been debated for half a century. Flows consistent with electro-osmotic instability have recently been observed in microfluidic experiments, but the existing theory neglects chemical effects and remains to be quantitatively tested. Here, we show that charge regulation and water self-ionization can lead to OLC by "current-induced membrane discharge" (CIMD), even in the absence of fluid flow, in ion-exchange membranes much thicker than the local Debye screening length. Salt depletion leads to a large electric field resulting in a local pH shift within the membrane with the effect that the membrane discharges and loses its ion selectivity. Since salt co-ions, H(+) ions, and OH(-) ions contribute to OLC, CIMD interferes with electrodialysis (salt counterion removal) but could be exploited for current-assisted ion exchange and pH control. CIMD also suppresses the extended space charge that leads to electro-osmotic instability, so it should be reconsidered in both models and experiments on OLC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Water Management in PEM Fuel Cells
Berg, P., Promislow, K., St. Pierre, J., Stumper, J., & Wetton, B. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1641033 · Cited by 353
Cited by
Water desalination via capacitive deionization: what is it and what can we expect from it?
Suss, M. E., Porada, S., Sun, X., Biesheuvel, P. M., Yoon, J., & Presser, V. (2015) · Energy & Environmental Science · doi:10.1039/c5ee00519a · Cited by 1,712
Self-citationElectrochemical Methods for Water Purification, Ion Separations, and Energy Conversion
Alkhadra, M. A., Su, X., Suss, M. E., Tian, H., Guyes, E. N., Shocron, A. N., Conforti, K. M., de Souza, J. P., Kim, N., Tedesco, M., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00396 · Cited by 661
Self-citationDesign principles of ion selective nanostructured membranes for the extraction of lithium ions
Razmjou, A., Asadnia, M., Hosseini, E., Habibnejad Korayem, A., & Chen, V. (2019) · Nature Communications · doi:10.1038/s41467-019-13648-7 · Cited by 616
Desalination at overlimiting currents: State-of-the-art and perspectives
Nikonenko, V. V., Kovalenko, A. V., Urtenov, M. K., Pismenskaya, N. D., Han, J., Sistat, P., & Pourcelly, G. (2014) · Desalination · doi:10.1016/j.desal.2014.01.008 · Cited by 405
Information Theory of Chemotactic Agents Using Both Spatial and Temporal Gradient Sensing
Rode, J., Novak, M., & Friedrich, B. M. (2024) · PRX Life · doi:10.1103/prxlife.2.023012 · Cited by 26
Metadata
- Authors
- Andersen, M. B., van Soestbergen, M., Mani, A., Bruus, H., Biesheuvel, P. M., & Bazant, M. Z.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2012-09-05
- Volume
- 109
- Issue
- 10
- Pages
- 108301-108301
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2169834631
- Cited by
- 166
- References
- 1
- FWCI
- 10.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Current-Induced Membrane Discharge. https://app.cochat.ai/papers/10.1103/physrevlett.109.108301
- The paper
- Andersen, M. B., van Soestbergen, M., Mani, A., Bruus, H., Biesheuvel, P. M., & Bazant, M. Z. (2012). Current-Induced Membrane Discharge. Physical Review Letters. https://doi.org/10.1103/physrevlett.109.108301
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.